Lead the heat discharge pipe outdoors.

Note on installing heat discharge pipe

In order to improve cooling efficiency,the heat discharge pipe should be as 
short as possible and flat without curve to ensure smooth heat discharge.
The discharge pipe is suggested to be installed according to below figure .

Discharge pipe can be installed based on user's requirement, while 
installation form as shown below should be avoided as it may lead to 
non-uniform exhaust.

• 

If the length of the heat discharge pipe is less than 1 meter. It is 
recommended to use it with shortest length.

• 

When installing, heat discharge pipe should be as flat as possible. Do not  
lengthen the pipe or connect it with an other heat discharge pipe.

Operation Test

• 

Connect power and then press ON/OFF button on remote control to 
start the unit.

• 

Press mode button to select auto, cooling, dry, fan or heating function, 
and then check if the unit operates normally.

• 

If ambient temperature is below 16°C , the unit can't operate in cooling 
mode.

Wiring Diagram

The electric schematic diagram are subject to change without notice. 
Please refer to the one on the unit.
UL-C10EA-W
UL-C12EA-W
UL-C10UA-W

R(M)

BOARD

DISPLAY

REC

RECEIVER

BOARD

SWITCH

WATER LEVEL

RT2

RT1

WATER MOTOR

POWER

L

BN(BK)

N

YEGN(GN)

BU(WH)

BU

N1

S

COMP

C

YE

C1

K201

AC-L

COMP

N2

WATER1

DISP2

RD

RD

BU

RD

DISP2

DISP1

AP2

M3

PE

PE

YEGN

DISP1

PE

PE

M2

OFAN

YEGN

MOTOR

DOWN FAN

C3

C2

RD

UP FAN

MOTOR

BN

M1

YEGN

FAN

AP3

AP1

MAIN BOARD

COMP.

CAP.

CAP.

RD

BN

CAP.

HIGH-WP

RD

RD

SA

SWING

M4

STEPPING

MOTOR

SENSOR

TUBE TEMP.

T-SENSOR

ROOM TEMP.

SENSOR

UL-CY12EA-W

R(M)

OUTTUBE 

RT3

BOARD

DISPLAY

REC

RECEIVER

BOARD

SWITCH

WATER LEVEL

RT2

RT1

OUTTUBE TEMP.

SENSOR

WATER MOTOR

POWER

L

BN(BK)

N

YEGN(GN)

BU(WH)

BU

N1

S

COMP

C

YE

C1

K201

AC-L

COMP

N2

WATER

DISP2

RD

RD

BU

RD

DISP2

DISP1

AP2

M3

PE

PE

YEGN

DISP1

PE

PE

M2

OFAN

YEGN

MOTOR

DOWN FAN

C3

C2

RD

UP FAN

MOTOR

BN

M1

YEGN

FAN

AP3

AP1

MAIN BOARD

COMP.

CAP.

CAP.

RD

BN

CAP.

N2

4YV 

4WAY

4-WAY

VALVE

HIGH-WP

RD

RD

SA

SWING

M4

STEPPING

MOTOR

SENSOR

TUBE TEMP.

T-SENSOR

ROOM TEMP.

SENSOR

Specialist's Manual

Aptitude requirement for maintenance personnel 
(repairs should be done only by specialists).

1. 

Any person who is involved with working on or breaking into a 
refrigerant circuit should hold a current valid certificate from an 
industry-accredited assessment authority, which authorises their 
competence to handle refrigerants safely in accordance with an 
industry recognised assessment specification.

2. 

Servicing shall only be performed as recommended by the equipment 
manufacturer. Maintenance and repair requiring the assistance of 
other skilled personnel shall be carried out under the supervision of 
the person competent in the use of flammable refrigerants.

Safety preparation work

The maximum refrigerant charge amount is shown on the following table.
(Note: Please refer to the nameplate for the charging quantity of R290).

Summary of Contents for UL-C10UA-W

Page 1: ...Product images are for illustration purposes only Actual product may vary EN UL C10UA W Portable air conditioner User manual ...

Page 2: ......

Page 3: ...OOL DRY LOCK AUTO H OPER 1 2 4 5 3 6 7 4 T OFF COOL DRY LOCK AUTO H OPER 1 6 7 2 3 4 8 9 10 11 5 14 12 13 5 5 6 7 8 9 11 10 12 2 1 2 4 3 1 1 2 3 6 8 9 10 11 14 13 12 7 4 5 3 only for model UL Y12EA W Images are for guidance only ...

Page 4: ...2 FAN ON OFF MODE SLEEP SWING TIMER SWING T ON T OFF COOL AUTO DRY FAN HEAT SLEEP LOCK SPEED H AUTO OPER 1 2 3 4 5 6 7 9 10 8 2 2 2 6 Images are for guidance only ...

Page 5: ...er than 11m The appliance is not to be stored in a room with continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation The appliance shall be stored so as to prevent mechanical damage from occurring Duct...

Page 6: ...reas Allow a gap of at least 30 cm around the appliance and ensure floor surface is smooth and flat Do not operate the air conditioner at humid environment Keep the air inlet and outlet clean and unobstructed During operation close doors and windows to improve cooling effect Locate the appliance on a smooth and flat surface to avoid excessive noise and vibration This air conditioner is equipped wi...

Page 7: ...6 Air inlet 7 Middle drainage port 8 Power cord 9 Power cord hooks 10 Plug storage space 11 Bottom drainage port 12 Castors NOTICE Some installation accessories can t be discarded Control Panel Refer to the pictures 3 on page 1 1 Fan speed indicator 2 Fan button 3 Swing button 4 Swing indicator 5 button 6 Display panel 7 Timer indicator 8 Timer button 9 Mode button 10 Cool mode indicator 11 Dry mo...

Page 8: ... MODE 3 4 FAN 5 SWING 6 SLEEP 7 TIMER Remote control display Refer to the pictures 5 on page 1 1 AUTO Auto mode 2 COOL Cool mode 3 DRY Dry mode 4 FAN Fan mode 5 HEAT Heat mode Cool and Heat models only 6 T ON Timer on 7 T OFF Timer off 8 SWING Swing operation 9 SLEEP Sleep operation 10 LOCK Lock 11 SPEED Set fan speed 12 Set temperature 13 Set time 14 Send signal Remote control functions NOTE ū Th...

Page 9: ...al between two motions can t exceed 5 seconds otherwise the remote control will exit setting status Functions by Combination Buttons Child lock function Press and buttons simultaneously can turn on or turn off child lock function When child lock function is started up child lock indicator on remote controller is ON If you operate the remote control remote control won t send signal This function wo...

Page 10: ... method Troubleshooting Before calling for service please review the troubleshooting list below since the problem may not be a main unit malfunction Air conditioner can t operate Cause Action Power failure Wait after power recovery Is plug loose Reinsert the plug Whether the air switch is tripped off or fuse is burnt Ask professional person to replace air switch or fuse Is there malfunction for th...

Page 11: ...intenance Prohibit incorrect operation to prevent electric shock casualty and other accidents Selection of installation location Basic requirement Installing the unit in the following places may cause malfunction If it is unavoidable please consult your dealer for advice 1 Locations with high temperature heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 Anywher...

Page 12: ...rom the middle drainage port NOTE ū Water can be automatically emptied into a floor drain by attaching 13 mm inner diameter hose not included 1 Remove the continuous drain cap by turning it counter clockwise then remove the rubber stopper from the spout 2 Screw the drain connector to included in the package the spout by turning clockwise 3 Insert a 13 mm inner diameter hose not included onto drain...

Page 13: ...P2 DISP1 AP2 M3 PE PE YEGN DISP1 PE PE M2 OFAN YEGN MOTOR DOWN FAN C3 C2 RD UP FAN MOTOR BN M1 YEGN FAN AP3 AP1 MAIN BOARD COMP CAP CAP RD BN CAP HIGH WP RD RD SA SWING M4 STEPPING MOTOR SENSOR TUBE TEMP T SENSOR ROOM TEMP SENSOR UL CY12EA W R M OUTTUBE RT3 BOARD DISPLAY REC RECEIVER BOARD SWITCH WATER LEVEL RT2 RT1 OUTTUBE TEMP SENSOR WATER MOTOR POWER L BN BK N YEGN GN BU WH BU N1 S COMP C YE C1...

Page 14: ...s and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded Checks to electrical devices R...

Page 15: ...ssential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to reuse of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Bec...

Page 16: ...upply 220 240V AC 50Hz Energy Efficiency Class Cooling A Heating N A Running Power Consumption Cooling W 935 Heating W N A Standby Power Consumption W 0 5 Cooling Capacity W 2900 Heating Capacity W N A Noise Level dB A Fan speed High Medium Low 65 64 62 Air Flow High Medium Low m h 385 355 325 Operating Temperature Range C 16 30 Room Size m 13 19 Size W x D x H in mm 393 x 425 x 804 Weight kg 32 5...

Page 17: ...EN ...

Page 18: ...16 ...

Page 19: ......

Page 20: ...www sharpconsumer eu Sharp Consumer Electronics Poland sp z o o Ostaszewo 57B 87 148 Łysomice Poland Made in China SDA MAN 0197 ...

Reviews: