Exception Clauses

Sharp will not be held responsible  for personal injury or loss to property 
for the following:

1. 

Any damage to the product caused by neglect, poor maintenance, 
incorrect handling or misuse;

2. 

Any altering, changing or use of the product with any other equipment 
which is not detailed in this User Manual;

3. 

If, after verification, damage or gas leakage has been caused by 
corrosive gas;

4. 

If, after verification, damage or gas leakage has been caused by 
incorrect transportation of the product;

5. 

Operate, repair, maintain the unit without abiding to the instructions in 
this User Manual or related regulations;

6. 

After verification, the problem or dispute is caused by the quality 
specification or performance of parts and components that have been 
produced by other manufacturers;

7. 

If any damage has been caused by natural calamities, bad using 
environment or force majeure.

• 

When refrigerant leaks or requires discharge during installation, 
maintenance, should carried out by certified professionals or otherwise 
in compliance with local laws and regulations.

• 

This appliance is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities or lack of 
experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety.

• 

Children should be supervised to ensure that they do not play with the 
appliance.

The Refrigerant

• 

To realize the function of the air conditioner unit, a special refrigerant 
circulates in the system. The used refrigerant is fluoride R290, which has 
been specially cleaned before installation to the refrigeration system. 
The refrigerant is flammable and inodorous. Furthermore, it can lead to 
explosion under certain conditions.

• 

Compared to common refrigerants, R290 is a nonpolluting refrigerant 
which does not harm the ozonosphere. The influence upon the 
greenhouse effect is also lower. R290 has got very good thermodynamic 
features which leads to a really high energy efficiency. The units 
therefore need a less filling.

Warning:

• 

Appliance filled with flammable gas R290.

• 

Appliance is recommended to be installed,operated and stored in a 
room with a floor area larger than 11m².

• 

The appliance is not to be stored in a room with continuously operating 
ignition sources. (for example: open flames, an operating gas appliance 
or an operating electric heater).

• 

The appliance shall be stored in a well-ventilated area where the room 
size corresponds to the room area as specified for operation.

• 

The appliance shall be stored so as to prevent mechanical damage from 
occurring.

• 

Ducts connected to an appliance shall not contain an ignition source.

• 

Keep any required ventilation openings clear of obstruction.

• 

Do not pierce or burn.

• 

Be aware that refrigerants may not contain an odour.

• 

Do not use means to accelerate the defrosting process or to clean, other 
than those recommended by the manufacturer.

• 

Servicing shall be performed only as recommended by the 
manufacturer.

• 

Should repair be necessary, contact your nearest authorized Service 
Centre. Any repairs carried out by unqualified personnel may be 

dangerous ,not covered under warrant and not supported by the 
manufacturer.

• 

Compliance with national gas regulations have to be observed.

Important safety instructions

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING

Risk of Fire / Flammable 

Materials

Please, read these safety instructions and respect 
the following warnings before the appliance is 
operated:

The lightning flash with arrowhead symbol, within an 
equilateral triangle, is intended to alert the user to the 
presence of uninsulated “dangerous voltage” within the 
product’s enclosure that may be of sufficient magnitude as to 
constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is 
intended to alert the user to the presence of important 
operating and maintenance (servicing) instructions in the 
literature accompanying the appliance.

This symbol means that the product should be disposed of 
in an environmentally friendly manner and not with general 
household waste.

Appliance filled with flammable gas R290.

Before using and installing the appliance, read the installation 
manual first.

"There are Specialists notes contained at the end of this User 
Manual which relate to the servicing of this product. These are 
only to be used by qualified persons."

Before using the appliance, read the owner’s manual first.

AC voltage

In order to prevent fi re always 

keep candles and other open 

fl ames away from this product.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for UL-C10UA-W

Page 1: ...Product images are for illustration purposes only Actual product may vary EN UL C10UA W Portable air conditioner User manual ...

Page 2: ......

Page 3: ...OOL DRY LOCK AUTO H OPER 1 2 4 5 3 6 7 4 T OFF COOL DRY LOCK AUTO H OPER 1 6 7 2 3 4 8 9 10 11 5 14 12 13 5 5 6 7 8 9 11 10 12 2 1 2 4 3 1 1 2 3 6 8 9 10 11 14 13 12 7 4 5 3 only for model UL Y12EA W Images are for guidance only ...

Page 4: ...2 FAN ON OFF MODE SLEEP SWING TIMER SWING T ON T OFF COOL AUTO DRY FAN HEAT SLEEP LOCK SPEED H AUTO OPER 1 2 3 4 5 6 7 9 10 8 2 2 2 6 Images are for guidance only ...

Page 5: ...er than 11m The appliance is not to be stored in a room with continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation The appliance shall be stored so as to prevent mechanical damage from occurring Duct...

Page 6: ...reas Allow a gap of at least 30 cm around the appliance and ensure floor surface is smooth and flat Do not operate the air conditioner at humid environment Keep the air inlet and outlet clean and unobstructed During operation close doors and windows to improve cooling effect Locate the appliance on a smooth and flat surface to avoid excessive noise and vibration This air conditioner is equipped wi...

Page 7: ...6 Air inlet 7 Middle drainage port 8 Power cord 9 Power cord hooks 10 Plug storage space 11 Bottom drainage port 12 Castors NOTICE Some installation accessories can t be discarded Control Panel Refer to the pictures 3 on page 1 1 Fan speed indicator 2 Fan button 3 Swing button 4 Swing indicator 5 button 6 Display panel 7 Timer indicator 8 Timer button 9 Mode button 10 Cool mode indicator 11 Dry mo...

Page 8: ... MODE 3 4 FAN 5 SWING 6 SLEEP 7 TIMER Remote control display Refer to the pictures 5 on page 1 1 AUTO Auto mode 2 COOL Cool mode 3 DRY Dry mode 4 FAN Fan mode 5 HEAT Heat mode Cool and Heat models only 6 T ON Timer on 7 T OFF Timer off 8 SWING Swing operation 9 SLEEP Sleep operation 10 LOCK Lock 11 SPEED Set fan speed 12 Set temperature 13 Set time 14 Send signal Remote control functions NOTE ū Th...

Page 9: ...al between two motions can t exceed 5 seconds otherwise the remote control will exit setting status Functions by Combination Buttons Child lock function Press and buttons simultaneously can turn on or turn off child lock function When child lock function is started up child lock indicator on remote controller is ON If you operate the remote control remote control won t send signal This function wo...

Page 10: ... method Troubleshooting Before calling for service please review the troubleshooting list below since the problem may not be a main unit malfunction Air conditioner can t operate Cause Action Power failure Wait after power recovery Is plug loose Reinsert the plug Whether the air switch is tripped off or fuse is burnt Ask professional person to replace air switch or fuse Is there malfunction for th...

Page 11: ...intenance Prohibit incorrect operation to prevent electric shock casualty and other accidents Selection of installation location Basic requirement Installing the unit in the following places may cause malfunction If it is unavoidable please consult your dealer for advice 1 Locations with high temperature heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 Anywher...

Page 12: ...rom the middle drainage port NOTE ū Water can be automatically emptied into a floor drain by attaching 13 mm inner diameter hose not included 1 Remove the continuous drain cap by turning it counter clockwise then remove the rubber stopper from the spout 2 Screw the drain connector to included in the package the spout by turning clockwise 3 Insert a 13 mm inner diameter hose not included onto drain...

Page 13: ...P2 DISP1 AP2 M3 PE PE YEGN DISP1 PE PE M2 OFAN YEGN MOTOR DOWN FAN C3 C2 RD UP FAN MOTOR BN M1 YEGN FAN AP3 AP1 MAIN BOARD COMP CAP CAP RD BN CAP HIGH WP RD RD SA SWING M4 STEPPING MOTOR SENSOR TUBE TEMP T SENSOR ROOM TEMP SENSOR UL CY12EA W R M OUTTUBE RT3 BOARD DISPLAY REC RECEIVER BOARD SWITCH WATER LEVEL RT2 RT1 OUTTUBE TEMP SENSOR WATER MOTOR POWER L BN BK N YEGN GN BU WH BU N1 S COMP C YE C1...

Page 14: ...s and signs that are illegible shall be corrected Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded Checks to electrical devices R...

Page 15: ...ssential that the technician is completely familiar with the equipment and all its detail It is recommended good practice that all refrigerants are recovered safely Prior to the task being carried out an oil and refrigerant sample shall be taken in case analysis is required prior to reuse of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Bec...

Page 16: ...upply 220 240V AC 50Hz Energy Efficiency Class Cooling A Heating N A Running Power Consumption Cooling W 935 Heating W N A Standby Power Consumption W 0 5 Cooling Capacity W 2900 Heating Capacity W N A Noise Level dB A Fan speed High Medium Low 65 64 62 Air Flow High Medium Low m h 385 355 325 Operating Temperature Range C 16 30 Room Size m 13 19 Size W x D x H in mm 393 x 425 x 804 Weight kg 32 5...

Page 17: ...EN ...

Page 18: ...16 ...

Page 19: ......

Page 20: ...www sharpconsumer eu Sharp Consumer Electronics Poland sp z o o Ostaszewo 57B 87 148 Łysomice Poland Made in China SDA MAN 0197 ...