SX
™
Service and Maintenance Manual 3-40 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
GREY RELAY 24V (con’t)
There are no adjustments necessary on the grey
Relay.
1. Remove the six screws holding the Frame
Cover, set screws and Frame Cover aside
(Figure 3-107).
2. Locate Grey Relay (Figure 3-108).
3. Using a small screwdriver, remove all wires
from Relay.
4. Remove Relay from DIN rail by taking a small
screwdriver and pulling tab out while pivoting
Relay back (Figure 3-109).
5. Remove Relay from DIN Rail.
6. Snap replacement Relay onto DIN rail, red LED
should be towards the outside.
7. Reconnect all wires (Table 3-2).
Table 3-2. Relay wire locations (Note: Lines in 11
and 14 are interchangeable).
Wire Label
Wire Color
Terminal Number
-
Dark Blue
11
-
Dark Blue
14
Y7
Dark Blue
A2
91
Dark Blue
A1
ADJUSTMENT
REPLACEMENT
Figure 3-107. Frame Cover Screws
Figure 3-108. Relay location
Figure 3-109. Removing Relay
Always remove electrical power from the
SX
prior to performing any maintenance
on the machine.
WARNING