SX™
Service and Maintenance Manual 3-139
960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
SEALER ASSEMBLY
STRIPPER PLATE SENSORS (con’t)
9. Follow the sensor cable back through the
machine, removing wire ties as necessary to
free the sensor from the machine. Unplug the
sensor from the 6-position junction box. The
left stripper plate sensor is plugged into
receptacle 5 (Figure 3-364).
10. Remove the sensor from the mounting block,
and install the new sensor (Figure 3-354).
11. Reinstall the left sensor and mounting block
into the machine (Figure 3-355).
12. Route the sensor cable through the machine,
following the same path the previous cable
took. Plug the sensor into receptacle 5 on the
6-position junction box. Secure sensor cables
to bundles inside the machine to keep wires
free of moving parts.
Setting Sensor Position (Both Sides)
13. Follow the steps outlined in the “Adjustment”
section to position the sensors in the correct
location.
14. Reinstall all guards removed in the previous
steps.
Left Sensor Plug
(Receptacle 5)
Figure 3-353.Stripper Plate Sensor Plugs
Figure 3-354. Sensor Mounting Block
Figure 3-355. Installing the Left Plate Sensor
Note: Side Plate Shown Clear for Clarity
Left Sensor
in Machine