9-11
#16. Body Breakage Or Cracks From Gullets
Probable Cause :
A.
Excessive back-up guide "preload".
B.
Improper band tension.
C.
Guide arms spread to maximum capacity.
D.
Improper beam bar alignment.
E.
Side guide adjustment is too tight.
F.
Excessively worn teeth.
#17. Band is Twisted Into A Figure "8" Configuration
Probable Cause :
A.
Excessive band tension.
B.
Any of the band conditions which cause the band
to be long (#18) or short (#19) on tooth edge.
C.
Cutting a tight radius.
#18. Used Band Is "Long" On The Tooth Edge
Probable Cause :
A.
Side guides are too tight – rubbing near gullets.
B.
Excessive "preload" – band riding heavily against
back-up guides.
C.
Worn band wheels causing uneven tension.
D.
Excessive feeding rate.
E.
Guide arms are spread to maximum capacity.
F.
Improper band tracking – back edge rubbing heavy
on wheel flange.
#19. Used Band Is "Short" On The Tooth Edge
Probable Cause :
A.
Side guides are too tight – rubbing near back edge.
B.
Worn band wheels causing uneven tension.
C.
Guide arms are spread too far apart.
D.
Excessive feeding rate.
Summary of Contents for SW-120NC
Page 1: ...SW 120NC Instruction Manual Version 3 20180105 ...
Page 2: ......
Page 8: ......
Page 13: ...1 5 Illustration Emergency Stop Emergency Stop Button ...
Page 17: ...1 9 Illustration Safety Labels SW 120NC ...
Page 23: ...2 5 FLOOR PLAN Machine top view Machine front view ...
Page 24: ...2 6 Machine side view ...
Page 66: ...5 2 Fig 5 1 Control panel layout ...
Page 67: ...5 3 Fig 5 2 Circuit board layout ...
Page 68: ...5 4 Fig 5 3 Power supply layout ...
Page 69: ...5 5 Fig 5 4 PLC input output layout ...
Page 70: ......
Page 71: ...6 1 Section 6 HYDRAULIC SYSTEM HYDRAULIC DIAGRAMS ...
Page 72: ...6 2 ...
Page 76: ......
Page 109: ......
Page 110: ......
Page 111: ......