Main code
Sub code
Content
26
20
Rear edge void setting
Used to set YES/NO of the paper rear edge void.
When this simulation is executed, the currently set rear edge void mode is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Rear edge void
0
Yes
←
Initial value
1
No
26
Auto shut off mode cancel
In Japan/SEC, the auto shut off function cannot be canceled by the user. In can be canceled by a serviceman.
(This simulation is available for all the destinations.)
Enter the set value and press the PRINT button to store it.
Set value
Set content
0
Auto shut off cancel inhibited
←
Initial value
1
Auto shut off cancel allowed
When this simulation is set to “1,” the value of “P3” in the user simulation becomes “0” and the mode change
cannot be made in the user simulation.
When this simulation is set to “0,” the value of “P3” in the user simulation is set as the initial value.
30
01
Paper sensor state display
Used to monitor the ON/OFF state of the sensors in the main body with the LED on the operation panel.
Sensor name
Operation panel LED
PID
Manual feed tray selection lamp
PPD
Drum position jam lamp (
▼
)
PPD1
Resist position jam lamp (
▼
)
PPD2
Main body lower step tray position jam lamp (
▼
)
PPD3
Paper empty lamp (
ç
)
PPD4
Jam lamp (
ê
)
POD
Paper exit position jam lamp (
▼
)
POD2
ADU position jam lamp (
▼
)
←
SF-2120 only
PED1
Body upper step tray selection lamp (
▼
)
←
SF-2020 only
PED2
Body lower step tray selection lamp
PED3
PFU upper step tray selection lamp
PED4
PFU lower step tray selection lamp
02
Tray size switch state display
Used to monitor the ON/OFF state of the tray size switch with the LED on the operation panel.
Selection of trays is made by the tray selection key.
Switch name
Operation panel LED
SW2
Paper exit position jam lamp (
▼
)
Switches are arranged
in the sequence of
SW2, SW1, and SW0
from the paper exit side.
SW1
Drum position jam lamp (
▼
)
SW0
Resist position jam lamp (
▼
)
Tray position
Each tray selection LED
8 – 11