Main code
Sub code
Content
26
06
Destination setting
Used to set the destination (Japan, SEC, etc.).
When this simulation is executed, the currently set destination is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Destination
0
Japan
1
SEC
2
SECL
3
SEEG
4
SUK
5
SCA
6
EX inch series
7
EX AB series
8
EX inch series (FC)
9
EX AB series (FC)
10
Taiwan/China
07
Drum sensitivity setting
Used to set the drum sensitivity.
When this simulation is executed, the currently set drum sensitivity is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Drum sensitivity
1
1
2
2
←
Initial value
3
3
10
AE original density setting
Used to set the original density.
When this simulation is executed, the currently set original density is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Original density
0
Normal
←
Initial value
1
Thin original
When a dark original is copied in the AE mode, the lead edge (about 4mm) is not copied. If it is necessary to copy
the lead edge, set this simulation to “1.”
13
Warm-up mode setting
Used to set the main motor operation mode during warm-up.
When this simulation is executed, the currently set warm-up mode is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Warm-up mode
0
Normal mode
←
Initial value
1
The main motor rotates until warm-up is completed.
18
Toner save mode setting (Japan/SUK only)
Used to set ON/OFF of the toner save mode.
When this simulation is executed, the currently set value is displayed on the copy quantity display.
Enter the set value and press the PRINT button to store it.
Set value
Toner save mode
0
ON
←
Initial value
1
OFF
8 – 10