40
E
SETUP menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
DATE/TIME SETTING
DATE
WR
AABBCCDDEE
AABBCCDDEE
AA: Year, BB: Month, CC: Day, DD: Hour, EE: Minute
○
LAN SETUP
DHCP client
DHCP
WR
0-1
0-1 0: OFF, 1: ON
IP Adress
IPAD
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than three digits, to three digits to fill zero.
Example: 192168150001
Subnet mask
SBMK
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than three digits, to three digits to fill zero.
Example: 255255255000
Default gateway
DFGW
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than three digits, to three digits to fill zero.
Example: 000000000000
DNS1
DNS1
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than three digits, to three digits to fill zero.
Example: 000000000000
DNS2
DNS2
WR
XXXXXXXXXXXX XXXXXXXXXXXX
X: Only number is ok. If the number is less than three digits, to three digits to fill zero.
Example: 000000000000
FTP ON/OFF
SELECT
FCHE
WR
0-1
0-1 0: FTP connection OFF, 1:FTP connection ON
MONITOR NAME
MNTR
WR
XXXXXXXX
XXXXXXXX
XXXXXXXX
XXXXXXXX
X: Sixteen characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
FTP Username
FUSR
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
FTP Password
FPAS
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field cannot be left blank, and spaces cannot be entered.)
Telnet
USERNAME
USER
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
Telnet
PASSWORD
PASS
WR
XXXXXXXX
XXXXXXXX X: Eight characters or less; half-width alphanumeric characters, “-”, and “_”.
(The field can be left blank, but spaces cannot be entered.)
ID SETTING
ID NO.SETTING
IDST
W
0-25
Sets the monitor’s ID number. (“0” means “no ID number”.)
R
0-25 Returns the monitor’s ID number.
ID NO. SETTING
(ONCE)
IDSL
W
1-25
Sets a monitor ID number.
This ID number is only effective for the command immediately after this
command.
0
Clears the ID number if one has been designated.
ID NO. SETTING
(SUBSEQUENT)
IDLK
W
1-25
Sets a monitor ID number.
This ID number is effective for the next and all subsequent commands after this
command.
0
Clears the ID number if one has been designated.
-
MULTI
ENLARGE
ENLG
WR
0-1
0-1 0: OFF, 1: ON
ENLARGE MODE
EMHV
WR
11-55
11-55
1 x 1 (OFF) to 5 x 5 (“m x n” is expressed as “mn”, where m and n are the
numbers of monitors specified for the longest direction and the shortest direction
respectively.)
IMAGE POSITION
(M x N)
EPHV
WR
11-55
11-55
Specifies values in the order of IMAGE POSITION IN LONGEST/ SHORTEST
DIRECTION.
BEZEL ADJUST
BZCO
WR
0-1
0-1 0: OFF, 1: ON
ENLARGE/
IMAGE POSITION
SETTING
ESHV
WR
XXYY
XXYY
XX: ENLARGE MODE (Same as EMHV), YY: IMAGE POSITION (Same as
EPHV)
THERMAL SENSOR SETTING
STDR
WR
0-3
0-3 0: LANDSCAPE, 1: PORTRAIT, 2: FACE UP, 3: FACE DOWN
○
ADJUSTMENT
LOCK
MONITOR
BUTTONS
ALCM
WR
0-1, 3
0-1, 3 0: UNLOCKED, 1: LOCK ALL, 3: LOCK EXCEPT POWER
REMOTE
CONTROL
ALCR
WR
0-3
0-3 0: UNLOCKED, 1: LOCK ALL, 2: LOCK EXCEPT VOLUME,
3: LOCK EXCEPT POWER
Autoplay
ATPL
WR
0-1
0-1 0: PHOTO, 1: MOVIE
ALL RESET
RSET
W
1
-
Controlling the Monitor with a computer (RS-232C)