41
E
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM
WR
0-31
0-31
○
MUTE
MUTE
WR
0-1
0-1 0: OFF, 1: ON
-
INFORMATION
MODEL
INF1
R
Value
○
SERIAL NO
SRNO
R
Value
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
1 Internal temperature abnormal has occurred and the monitor is in standby mode
2 Internal temperature abnormal occurred (To delete the information of temperature
abnormal, turn off the main power.)
3
Internal temperature abnormal has occurred and backlight brightness is dimmed
4 Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value
Returns the temperature at the temperature sensors in the following format.
[Sensor 1]
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
R
0
No detectable error has occurred
1 Standby mode by POWER button
3
Standby mode by RS-232C or LAN
4
Input signal waiting mode by No Signal
6
Standby mode by abnormal temperature
8
Standby mode by SCHEDULE setting
20 Standby mode by OFF IF NO OPERATION setting
TIPS
• Some menu setting items do not have a command. Set with the remote control during installation.