32
E
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
ALL RESET
RSET
W
0
-
ADJUSTMENT LOCK
ALCK
WR
0-2
0-2 0: OFF, 1:ON 1, 2:ON 2
-
OSD DISPLAY
LOSD
WR
0-2
0-2 0: ON 1, 1: OFF, 2: ON 2
-
LED
OFLD
WR
0-1
0-1 0: ON, 1: OFF
-
TEMPERATURE ALERT
TALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
-
STATUS ALERT
SALT
WR
0-2
0-2 0: OFF, 1: OSD & LED, 2: LED
-
Others
Function
Command Direction
Parameter
Reply
Control/Response contents
*
VOLUME
VOLM
WR
0-31
0-31
-
BRIGHT
VLMP
WR
0-31
0-31
-
TEMPERATURE SENSOR
DSTA
R
0
Internal temperature normal
●
1
Internal temperature abnormal has occurred and the monitor is in
standby mode
2
Internal temperature abnormal occurred (To delete the information of
temperature abnormal, turn off the main power.)
3
Internal temperature abnormal has occurred and backlight brightness is
dimmed
4
Temperature sensor abnormal
TEMPERATURE ACQUISITION
ERRT
R
Value Returns the temperature of the temperature sensor.
Indicates a temperature sensor abnormality when “126” is returned.
-
CAUSE OF LAST STANDBY MODE
STCA
W
0
Initialization
●
R
0
No detectable error has occurred
1
Standby mode by POWER button
2
Main power off by the main power switch
3
Standby mode by RS-232C
4
Input signal waiting mode by No Signal
6
Standby mode by abnormal temperature
20
Standby mode by OFF IF NO OPERATION setting