LC-32LE340/343
LC-40LE340/343
45
17.
LNB supply and control IC
ST LNBH23L
a) Key Features
Ŷ&RPSOHWHLQWHUIDFHEHWZHHQ/1%DQG,ð&EXV
Ŷ%XLOW
-in DC-DC converter for single 12 V supply operation and high efficiency (typ. 93%
@0.5 A)
Ŷ6HOHFWDEOHRXWSXWFXUUHQWOLPLWE\H[WHUQDOUHVLVWRU
Ŷ&RPSOLDQWZLWKPDLQVDWHOOLWHUHFHLYHUVRXWSXWYROWDJHV
pecification
Ŷ$X[LOLDU\PRGXODWLRQLQSXW(;70SLQIDFLOLWDWHV'L6(T&;HQFRGLQJ
Ŷ$FFXUDWHEXLOW
-in 22 kHz tone generator suits widely accepted standards
Ŷ/RZ
-drop post regulator and high efficiency step-up PWM with integrated power NMOS
allow low power losses
Ŷ2YHUORDGDQGRYHU
-temperature internal protections with I²C diagnostic bits
Ŷ/1%VKRUWFLUFXLWG\QDPLFSURWHFWLRQ
Ŷ
- 4 kV ESD tolerant on output power pins
Applications
Ŷ67%VDWHOOLWHUHFHLYHUV
Ŷ79VDWHOOLWHUHFHLYHUV
Ŷ3&FDUGVDWHOOL
te receivers
Description
Intended for analog and digital satellite receivers, the LNBH23L is a monolithic voltage
regulator and interface IC, assembled in QFN32 5 x 5 specifically designed to provide the 13 /
18 V power supply and the 22 kHz tone signalling to the LNB down-converter in the antenna
dish or to the multi-switch box. In this application field, it offers a complete solution with
extremely low component count, low power dissipation together with simple design and I²C
standard interfacing.
46
b) Block Diagram
18.
Software Update
18.1 Main SW update
In MB70 project you can update the main IC software by using USB ports. You can find the
SW update procedure below.
1. Software files should copy directly inside of a flash memory(not in a folder).
2. Put flash memory to the tv when tv is powered off.
3. Power on the and wait. TV will power-up itself.
4. If First Time Installition screen comes, it means software update procedure is succesful.
5. You can check the SW release name from service menu.
18.2 Panel Configuration File update
In MB70 project you can update the panel Configuration file by using USB ports. You can
find the update procedure below.
1. Please copy panel configuration files to USB root.
2. Turn power to OFF by remote controler and plug the USB to TV.
3. Turn power to ON by using remote controler.
4. TV standby led will blink rapidly during the sw update. Please wait approximately for 1-2
minutes.
5. TV will open automatically with the new panel configurations
.
64
LC-40LS340
Summary of Contents for LC-40LS340E
Page 27: ...11 c Absolute Ratings d Recommended Operating Conditions e Pin Functions 27 LC 40LS340 ...
Page 37: ...21 c BCM3556 Block Diagram 37 LC 40LS340 ...
Page 46: ...LC 32LE340 343 LC 40LE340 343 30 b Pinning 46 LC 40LS340 ...
Page 52: ...LC 32LE340 343 LC 40LE340 343 35 c Pinning 52 LC 40LS340 ...
Page 57: ...39 15 LOW POWER CEC MICROCONTROLLER NEC uPD78F0503 Pinning 57 LC 40LS340 ...
Page 59: ...b Block Diagram 59 LC 40LS340 ...
Page 60: ...LC 32LE340 343 LC 40LE340 343 Figure 8 Pin Diagram 60 LC 40LS340 ...
Page 74: ...LC 32LE340 343 LC 40LE340 343 57 Video Settings Audio Settings 74 LC 40LS340 ...
Page 75: ...58 Options 1 Menu Options 2 Menu 75 LC 40LS340 ...
Page 76: ...LC 32LE340 343 LC 40LE340 343 59 Tuner Settings Menu Source Settings Menu 76 LC 40LS340 ...
Page 77: ...60 Diagnostic Menu 21 General Block Diagram 77 LC 40LS340 ...
Page 78: ...LC 32LE340 343 LC 40LE340 343 NOTES 78 LC 40LS340 ...
Page 100: ...LC 32LE340 343 LC 40LE340 343 NOTES 100 LC 40LS340 ...
Page 121: ...NOTES 121 LC 40LS340 ...