6-6
Chapter 6: Connection/Wiring
6
Wiring the power source
When a 10BASE5 is used, 12 VDC power should be supplied to the transceiver.
Supply power to the 12 VDC power supply input terminal of the Z-336J using a commercial constant
voltage power supply unit.
Remarks
- Use a power supply that is dedicated for use by the Z-336J.
- Do not reverse the positive and negative connections to the power terminals. Reversing the polarity
may damage the Z-336J.
Item
Specifications
Supply voltage
Current capacity
12 VDC
–
5%
0.5 A minimum.
(+)(−)
2
1
O
F
F
SWA
ON
SW1
SW6
ON
S0
S1
S2
S3
S4
S5
S6
S7
HE
PE
T
12V
RX
TX
LN
Z-336J
12 VDC
* Fuse (0.6 A)
Black wire (-)
Red wire (+)
Twisted pair wires
Case
Green wire
(ground)
Cable
* Use a fuse that will melt with
time lag
12 VDC power supply input terminal
(Accessory: Connector,
cable length 1.5 m)