9-29
Chapter 9: Message transfers
9
Monitoring register COM = 24
(H)
[Format]
COM
= 24
(H)
DSEG
= Segment (00 to 07, 10 to 2C
(H)
)
See page 9-20.
DADR
L, H
= Byte address (0000
(H)
to FFFF
(H)
)
See page 9-20.
L
L, H
= Data length (Number of bytes)
DATA
1 to N
= Read data
[Function]
- Read the register data with the length shown by L, starting from DSEG, DADR.
- Up to 1024 bytes can be read at a time.
[Execution condition]
- Write enable mode
: Mode 0, mode 1 and mode 2
- PC operation status
: Stopping, operating
[Example]
- Read 4 bytes data from register 09000 to 09003.
Ë
Command
Ë
Response
COM
DSEG DADR
L
DADR
H
L
L
L
H
COM
RSLT DSEG DADR
L
DADR
H
L
L
L
H
DATA
1
DATA
N
......
File address
0800
(H)
= 004000
(8)
File number 0
File number 0
Ë
Command
Ë
Response
24
00
00
08
04
00
24
00
00
00
08
04
00
00
4F
32
01
Top register
number 09000
Top register
number 09000
File address
0800
(H)
= 004000
(8)
Data length
Data length
Value at
09000
Value at
09001
Value at
09002
Value at
09003