background image

6

Dry the filter outdoors

if possible in a well

ventilated area.

CAUTION

• The wet filter is heavy. Fix it securely for drying to

make sure it does not fall down.

• The filter takes longer to dry in winter, on rainy days.

Wash it on a day when the weather is good and
dry it in the sun.
Move it indoors at night to prevent freezing.

• Dry the filter outdoors in a well ventilated area. If

dried indoors, the water dripping off the filter may
soil your floor.

• Make sure that the activated carbon has not shifted

to one side inside the filter. If it has, distribute it
evenly with your fingers.

• Let the filter dry thoroughly.

If used while the filter is still moist, then the air that
is exhausted from the main unit will have an odour.
It may take 1 or 2 days to dry.

7

Reinstalling the Filter.

Reinstall the filter as shown on Page E-6,7

8

Once the Active Carbon Filter has

been cleaned, connect the power

cord to the outlet and press the Filter

Reset Button on either the  Remote

Control or Main Unit.

E-12

CARE AND MAINTENANCE

WASHABLE ACTIVE CARBON FILTER CARE

Care Cycle

When the Filter Indicator Light lights up,

this indicates that the filter needs to be

cleaned. If the unit is kept on 24 hours a

day then the Filter Indicator Light will be

activated in about 2 months.

The Filter Indicator Light is for reference.

Clean the filter as often as necessary

when odour persists.

1

Remove

visible dirt

with a

vacuum

cleaner.

2

Fill a large container up with

warm water, add a mild

kitchen detergent and stir.

Dilute as indicated
on the detergent

container.

3

Allow the filter to soak ap-

proximately 30 minutes be-

fore washing.

If the filter surface

is very dirty, scrub
with an old tooth-

brush.

CAUTION

Handle with care to
prevent damage to
the activated carbon
particles.

4

Rinse thoroughly with clean

water

CAUTION

If rinsing in a con-
tainer, be sure to
rinse 3 to 4 times so
that the odour is
rinsed thoroughly
from the filter.

5

Remove excess water

The filter will be saturated with water after rins-

ing. To decrease drying time, wrap the filter in
an old thick towel so that excess water can be

removed.

CAUTION

Some carbon may adhere to
the towel, but it is harmless.

HAND WASH ONLY!
DO NOT TUMBLE DRY!

• Once the Filter Reset Button has been acti-

vated, you will hear a beep sound that means

the unit has been reset.

• The Filter indicator light will then go out

automatically.

Filter Reset Button

Summary of Contents for FU-P60S

Page 1: ...ENGLISH FU P60S AIR PURIFIER OPERATION MANUAL R ENGLISH Free Standing Plasmacluster is a trademark of Sharp Corporation Plasmacluster ...

Page 2: ......

Page 3: ... Filters 1 Pre Filter It collects large particles 2 Washable Active Carbon Filter Its deodorizing performance can be maintained by washing 3 HEPA High Efficiency Particulate Air Filter with Microbial Control Filter High efficiency particle collection in cluding pollen and dust CONTENTS IMPORTANT SAFETY INSTRUCTIONS E 2 WARNING E 2 CAUTIONS CONCERNING OPERATION E 2 REMOTE CONTROL LIMITATIONS E 2 IN...

Page 4: ...t cigarettes chemical fumes in the air or under a humid condition Use with care when cleaning the air purifier Strong corrosive cleansers may damage the exterior Only Sharp Authorized Servicers should service this air purifier Contact the nearest Servicer for any problems adjustments or repairs The batteries must be removed from the remote control before disposal and the batteries must be disposed...

Page 5: ...ructions in this manual for correct care and maintenance of the filters HOW SHARP AIR PURIFIER WORKS An air purifier draws in room air from its air intake lets the air pass through an Active Carbon Filter Deodorizing Filter and a HEPA Filter dust collection filter inside of the unit then discharges the air from its air outlet The air purifier repeats this process by moving its internal fan As air ...

Page 6: ...el Hook Remote Control 1 unit Battery AA battery x 2 Operation manual Remote Control Receiver Filter Indicator Light CLEAN SIGN Light Plasmacluster Indicator Light AUTO Operation Indicator Light 15min HIGH operation Indicator Light Pollen Mode Indicator Light Fan Speed Indicator Lights OFF Timer Display In dicator Lights Sensor Sensitivity Select Switch Filter Reset Button Sensor sensitivity can b...

Page 7: ... batteries The batteries are for initial use only and may be depleted within 1 year INSERTING BATTERIES IN THE REMOTE CONTROL 1 Remove the back cover Press and slide the back cover to remove 2 Insert batteries Insert batteries with and as shown below 3 Close the back cover REMOTE CONTROL USE Operate the remote control facing the main unit receiver The signal range is about 7m Make sure there are n...

Page 8: ...Front Panel Pull the bottom of the Front Panel 3 Remove the Active Carbon Filter black and HEPA Filter white from the plastic bags E 6 Be sure to remove the power plug from the wall outlet FILTER INSTALLATION 2 Pull out the Filter Frame and remove the Pre Filter Active Carbon Filter and HEPA Filter Front Panel Filter Frame Pre Filter Pre Filter Active Carbon Filter HEPA Filter Filter Frame Active ...

Page 9: ...lace the Pre filter through the bands 2 places located at the corners of the Active Carbon Filter Insert the tabs of the pre filter into the associated holes of the Filter Frame 5 Fill in the usage start date on the Date Label Use the date as a guide for the Filter Replacement schedule 4 Mount the Filter Frame to the main unit Tabs HEPA Filter Filter Frame Band Active Carbon Filter HEPA Filter Fil...

Page 10: ...NORMAL and HIGH for 20 minutes 10 minutes HIGH fan speed 20 minutes NORMAL fan speed 20 minutes HIGH fan speed Main Unit Controls AUTO 15 min HIGH POLLEN SILENT NORMAL MAX Clean Sign Light Power ON OFF Button Used to start operation short beep and stop operation long beep Plasmacluster Indicator Light and Fan Speed Indicator Light turn on off Unless unplug the power cord the operation starts in th...

Page 11: ...lug is inserted into the wall outlet It is possible to have a green CLEAN SIGN with impurities in the air at the time that the air purifier was just introduced to the room environment After a while however the base impurity rate will be adjusted to detect room air condition correctly Use the Display ON OFF Button on the remote control to turn off the Indicator light Clean Green Slightly Impure Ora...

Page 12: ... switches every time the button is pressed as shown below The indicator light shows the remaining time The unit will stop operation when the timer is up 1 hour Cancel 4hours 8 hours Plasmacluster Ion Mode Selections AUTO When pressed the unit will switch between Clean Mode and the Ion Control Mode automatically de pending on the amount of impurities in the air as detected by the dust and odour sen...

Page 13: ...ers CARE AND MAINTENANCE To maintain optimum performance of this air purifier please clean the unit including the sensors and filters periodically When cleaning the unit be sure to unplug the power cord and never handle the plug with wet hands Electrical shock and or bodily injury may occur as a result MAIN UNIT ODOUR SENSOR DUST SENSOR Hole of odour sensor E 11 Remove the Front Panel Clean the su...

Page 14: ...Light lights up this indicates that the filter needs to be cleaned If the unit is kept on 24 hours a day then the Filter Indicator Light will be activated in about 2 months The Filter Indicator Light is for reference Clean the filter as often as necessary when odour persists 1 Remove visible dirt with a vacuum cleaner 2 Fill a large container up with warm water add a mild kitchen detergent and sti...

Page 15: ...opening REPLACING THE FILTERS 1 See page E 6 7 for directions on how to install the filters when replacing 2 After replacing the filters Be sure to press the Filter Reset Button on the Remote Control with the power cord connected to the outlet A short beep will be heard and the operation hours stored in the memory will be reset The Filter Indicator Light will then go out automati cally 3 Fill in t...

Page 16: ...d air has an aroma or odour Check to see if the filters are heavily soiled Replace the filters Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour The amount of ozone emitted by the ion generator is very little which is below the safety levels set by the IEC 60335 2 65 and it is harmless to the human body The Plasmacluster Indicator Light remains green or blue and doe...

Page 17: ... 4 0 W 36 m3 hour The applicable floor surface area is the surface area for operating the unit in MAX fan level Applicable floor surface area indicates the space where a certain amount of dust particle can be removed in 30 minutes Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet this product consumes about 0 7W of standby power For energ...

Page 18: ......

Page 19: ... C 1 ...

Page 20: ...C 2 ...

Page 21: ... C 3 HEPA Filter Active Carbon Filter ...

Page 22: ...C 4 ...

Page 23: ...1 2 3 C 5 ...

Page 24: ...1 1 2 2 1 1 2 1 1 2 3 C 6 ...

Page 25: ...C 7 2 1 2 3 5 4 ...

Page 26: ...Plasmacluster 1 2 C 8 1 2 ...

Page 27: ...C 9 OPERATION ...

Page 28: ... Plasmacluster C 10 ...

Page 29: ...C 11 ...

Page 30: ...C 12 1 2 4 3 5 6 8 7 ...

Page 31: ...C 13 1 2 3 ...

Page 32: ...C 14 ...

Page 33: ...C 15 ...

Page 34: ......

Page 35: ...MEMO ...

Page 36: ...SHARP CORPORATION TINS A154KKRZ 05FO CN 2 ...

Reviews: