Measurement of power consumption
While in the test mode, the power consumption is measured.
It is stopped and finished by pressing the Operation ON/OFF button.
Error table
No.
Item
Error display/status
Cause
Solution
1
No. 1
Clean sign is flashing.
EEPROM communication
Replace the circuit PWB.
2
No.1 - No.10 Silent lamp is flashing.
Fan motor revolution speed
Replace the fan motor.
Check the insertion of the
fan motor connector.
(2) Demo mode
1) Outline
............................. The demo mode (display mode) is used for demonstration of displays in shops.
2) Setting procedure ................. While operating in the pollen mode, press the " Operation selector/OFF " button
............................. to stop the operation, and hold it down for three seconds or more.
............................. When the " Pollen " button on the remote control is pressed while holding it
............................. down, a pip sound is heard and the unit starts the demo mode.
3) Cancellation procedure .......... While holding down the " Operation selector/OFF " button for three seconds or
............................. more, press the " Pollen " button.
............................. A bleep sound is heard and the demo mode is canceled, and the unit is stopped
............................. in the normal mode.
4) Switch operation .................... Only the demo mode canceling operation is enabled.
5) LED indicator ......................... (a) Power lamp
.... : Always lit.
............................. (b) Clean sign
.... : Undetected mode is displayed (as described below).
............................. (c) Cluster lamp
.... : The blue and green LEDs are lit alternately at one-
.............................
....
second intervals (as described below).
............................. (d) Others
.... : Lit and distinguished as shown in the table below at
.............................
....
one-second intervals.
6) Load output ............................. (a) Odour sensor drive output : equivalent intermittent output with the normal stop
.............................
....
(Refer to 17. " Odor sensor drive output ".)
............................. (b) Other outputs
....
: OFF
(3) Aging mode
1) Outline
............................. In this mode, several operation modes can be repeated automatically to perform
............................. life test of loads, materials, and driving equipment.
2) Setting procedure ................... Turn the power on while holding down the " Operation selector/OFF" button on
............................. the main unit. While pressing it down, press the " Silent " button within five
............................. seconds. A bleep sound is heard and the unit starts the aging mode.
3) Cancellation procedure .......... It can be canceled only by cutting the power supply.
4) LED indicator ......................... (a) Power lamp : Always lit.
............................. (b) Timer lamp : " 1 hour " and " 8 hours " are always lit (mode display).
............................. (c) Others: Same as the normal mode.
5) Operation
............................. (a) Programmed operation in the following sequence.
1
Green Orange Red Orange
Blue Green Blue Green
Green
Blue
Orange
Green
Red
Blue
Orange
Green
Demo mode display No.
Power
Clean sign
Cluster lamp
Operation mode lamp
Auto
Silent
Median
High
Max
Tobacco
Pollen
Note
[The contents of a display]
2
3
4
5
6
7
8
: ON
: OFF
Max
Aging mode
injection
after 10 min.
after 10 min.
after 10 min.
ion aout
Silent
ion clean
Under a stop
ion off