SW-A5 No. 5, No. 6 Digital cable equalizer setting
(Reception for Caller ID)
Line equalization when reception for CALLER ID is to be set accord-
ing to the line characteristics.
Setting should be made according to distance between the telephone
and the telephone company central switching station.
SW-A5 No. 7 Error criterion
Used to select error criterion for sending back RTN when receiving
image data.
SW-A5 No. 8 Anti junk fax check
When use the Anti junk fax function, set to "1".
SW-A6 No. 1 Auto gain control (MODEM)
When this mode is enabled, if the reception signal level is under
31dBm. The modem itself controls the signal gain automatically.
SW-A6 No. 2 End buzzer
Setting this bit to 0 will disable the end buzzer (including the error
buzzer/on-hook buzzer).
SW-A6 No. 3 Disconnect the line when DIS is received in RX
mode
Bit1= 0: When DIS signal is received during RX mode, the line is
disconnected immediately.
Bit1= 1: When DIS signal is received during RX mode, the line is
disconnected on the next tone.
SW-A6 No. 4 Equalizer freeze control (MODEM)
This switch is used to perform reception operation by fixing the equal-
izer control of modem for the line which is always in an unfavorable
state and picture cannot be received.
* Usually, the control is executed according to the state of line where
the equalizer setting is changed always.
SW-A6 No. 5 Equalizer freeze control 7200BPS only
Setting which specifies SW-A3 No. 6 control only in the condition of
7200BPS modem speed.
SW-A6 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B1 No. 1 ~ No. 4 Recall interval
Choice is made for a redial interval for speed and rapid dial calls.
Used a binary number to program this. If set to 0 accidentally, 1 will
be assumed.
SW-B1 No. 5 ~ No. 8 Recall times
Choice is made as to how many redials should be.
SW-B2 No. 1 Dialing pause (sec/pause)
Pauses can be inserted between telephone numbers of direct dial
connection. Selection of 4 sec or 2 sec pause is available.
SW-B2 No. 2, No. 3 Reserved
Set to "0".
SW-B2 No. 4 Busy tone detection (after auto dial)
Used to set busy tone detection in auto dialing.
SW-B2 No. 5 Waiting time after dialing
This is time waiting for the opponent’s signals after dialing.
For the Switzerland version, the time is fixed to 90 seconds regard-
less of this switch setting.
SW-B2 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-B4 No. 1 Auto dial mode Delay timer of before line connect
Delay time between the dial key input and line connection under the
auto dial mode.
SW-B4 No. 2 Auto dial mode Delay timer of after line connect
Delay time between the line connection and dial data output under
the auto dial mode.
SW-B4 No. 3 Dial mode
When using the pulse dial, set to 1. When using the tone dial, set to
0.
SW-B4 No. 4 Pulse
→
Tone change function by
key
When setting to 1, the mode is changed by pressing the
key from
the pulse dial mode to the tone dial mode.
SW-B4 No. 5 ~ No. 8 Reserved
Set to "0".
SW-B5 No. 1 ~ No. 5 DTMF signal transmission level (Low)
The transmission level of DTMF signal is adjusted. (lower frequency)
00000: 0dBm
↓
11111: -15.5dBm (-0.5dBm x 31)
SW-B5 No. 6 ~ No. 8 Reserved
Set to "0".
SW-B6 No. 1 ~ No. 5 DTMF signal transmission level (High)
The transmission level of DTMF signal is adjusted. (higher frequency)
00000: 0dBm
↓
11111: -15.5 dBm (-0.5dBm x 31)
SW-B6 No. 6 ~ No. 8 Reserved
Set to "0".
SW-C1 No. 1, No. 2 Reading slice (Binary)
Used to determine the set value of reading density in standard/fine
mode. The standard setting is "00" (Factory setting is "00")
SW-C1 No. 3, No. 4 Reading slice (Half tone)
Used to determine the set value of reading density in half tone mode.
The standard setting is "00" (Factory setting is "00")
SW-C1 No. 5 Line density selection
Used to set the transmission mode which is automatically selected
when the Resolution key is not pressed. In the copy mode, however,
the fine mode is automatically selected unless the Resolution key is
manually set to another mode.
SW-C1 No. 6 ~ No. 8 Reserved
Set to "0".
RAPID01
CML RELAY ON
DIALLING
0 : 0sec
1 : 3sec
RAPID01
CML RELAY ON
0 : 1.7sec
1 : 3sec
DIAL DATA
UX-510U/UX-510C/UX-500U
UX-500C/FO-1460U
2 – 13
Summary of Contents for FO-1460
Page 69: ...Control PWB parts layout Top side 6 7 UX 510U UX 510C UX 500U UX 500C FO 1460U ...
Page 70: ...Control PWB parts layout Bottom side 6 8 UX 510U UX 510C UX 500U UX 500C FO 1460U ...
Page 72: ...TEL LIU PWB parts layout 6 10 UX 510U UX 510C UX 500U UX 500C FO 1460U ...
Page 74: ...6 12 Power supply PWB parts layout UX 510U UX 510C UX 500U UX 500C FO 1460U ...
Page 77: ...Operation panel PWB parts layout 6 15 UX 510U UX 510C UX 500U UX 500C FO 1460U ...