Main code
Sub code
Content
26
38
Cancel of stop at drum life over
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
39
Memory capacity setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
40
Polygon motor OFF time setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed.
42
Transfer ON timing control setup
(Operation / Procedure)
1. When this simulation is executed, the currently set code number is displayed.
2. Enter the code number and press the START key, and the setting will be changed. (For any number different
from the following ones, the default time is automatically set.)
Code number
Setting
0
Stop at drum life over
1
Stop cancel at drum life over
Code number
Setting
0
No memory
1
4 Mbyte
2
6 Mbyte
Code number
Setting
0
0 sec
1
30 sec
2
60 sec
3
90 sec
Code number
Setting
0
Default (330 msec)
1
–40 msec
2
–30 msec
3
–20 msec
4
–10 msec
5
Default (330 msec)
6
+10 msec
7
+20 msec
8
+30 msec
9
+40 msec
DM-1505
9 – 6