CS-4194H Servicing
– 6 –
(5) Insulation sheet (Small) attachment
Attach the insulation sheet (Small) to insulate the printer motor wiring.
(6) Wiring of the secondary side of the transformer
Pass the lead wire of the secondary side of the transformer through the
slit section of the rib on the upper cabinet, and attach UL tape to the slit
section to fix the lead wire.
(7) Protection tube
(7)-1. CS-4194H (AAC, ACO)
Insulate between the transformer and the AC cord connector with pro-
tection tubes (2 pcs
u
2 positions).
(7)-2. CS-4194H (TRC)
The CS-4194H (TRC) uses 14 protection tubes in total (that is, 2 pcs
u
7
positions) as shown above.
Insulation sheet (Small)
Attach the insulation sheet (Small) to
prevent the printer motor wiring from
being damaged by the solder section
on the back of the printer PWB.
Insulation sheet (Small)
Fold the insulation sheet (Small) to
secure the printer motor wiring.
printer motor wiring
UL tape
Cross section of the upper cabinet
Rib
Attach UL tape to keep the
lead wire inside the groove.
Lead wire
Transformer
Protection tube (2 pcs)
Protection
tube (2 pcs)
Protection tube
(Heat contraction tube)
2 pcs/position
5 positions
[VOLTAGE SELECTOR]
Protection tube
(One: Outside)
Protection tube
(One: Inside)
Use two protection tubes at
every one position.
[FUSE HOLDER]
Fuse
holder
Protection tube
(2 pcs)
Protection tube