AL-1661CS TEST COMMAND, FAX SOFT SWITCH, TROUBLE CODES 10 - 42
S
W
15
1
Busy tone detection
time (Lower limit)
1: 350ms
0: 250ms
250ms
0
2
Busy tone detection
time (Upper limit)
1: 650ms
0: 750ms
750ms
0
3
Busy tone detection
time (Lower limit 2)
1: 150ms
0: Follows SW15-1.
Follows SW15-1. 0
4
Signal send level
Binary input
–12dBm
0 When a value outside
the set range is set,
the initial value is set.
5
Bit No.
Set range
4
5
6
7
8
0 (0dBm) to 26 (–26dBm)
1
6
1
7
0
8
0
S
W
16
1
Modem speed
(V.33 mode or less)
Bit No.
1
2
3
4
V.17 14.4kbps
1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
2
V.27 4800bps
0
0
1
0
0
V.29 7200bps
0
0
1
1
V.33 14.4kbps
0
1
0
0
3
V.33 12.0kbps
0
1
1
0
0
V.17 9600bps
1
0
0
1
V.17 12.0kbps
1
0
1
0
4
V.17 7200bps
1
0
1
1
0
V.17 14.4kbps
Others
5
Modem speed in
reception fixed
Bit No.
5
6
No fixing
0
No fixing
0
0
V.29-9600BPS
0
1
6
V.27ter-4800BPS
1
0
0
V.17-14400BPS
1
1
7
Inhibited to use
0
8
0
S
W
17
1
Inhibited to use
0
2
MH fixed (Except for
SG3)
1: Yes
0: No (depending on the other
party’s machine)
No
0
3
ECM MMR (Except for
SG3)
1: Yes
0: No
Yes
1
4
ECM JBIG (Except for
SG3)
1: Yes
0: No
Yes
1
5
Inhibited to use
0
6
MH fixed (in SG3)
1: Yes
0: No (depending on the other
party’s machine)
No
0
7
ECM MMR (in SG3)
1: Yes
0: No
Yes
1
8
ECM JBIG (in SG3)
1: Yes
0: No
Yes
1
S
W
18
1
Inhibited to use
1
2
1
3
0
4
1
5
0
6
0
7
0
8
0
S
W
19
1
Inhibited to use
0
2
1
3
0
4
0
5
0
6
Recording table
automatic print
1: Yes
0: No
No
0
Refer to User program
“AUTO LISTING”.
7
Inhibited to use
0
8
0
SW
NO.
Data
No.
Item
Switch selection and contents of functions
Initial value
Remark