AL-1651CS TEST COMMAND, TROUBLE CODES 10 - 15
43
05
Fusing temperature setting
in duplex copy (FU TEMP
DPLX)
[Function]
In the case of duplex copy, the shift temperature set with this test command is applied to the fusing
temperature.
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
[Operation]
The operation is similar to test command 21-01.
09
Postcard size paper fusing
control setting (FU CTR P-
CARD) (Japan model only)
[Function]
When this test command is executed, the current set code number is displayed.
Enter the desired code number and press [ENTER/START] key to save the setting.
∗
Setting" is default for Japan. However, there is no schedule for production of the Japan model.
[Operation]
The operation is similar to test command 21-01.
11
Postcard size paper fusing
temperature setting (FU
TEMP P-CARD) (Japan
model only)
[Function]
When this test command is executed, the current set code number is displayed.
When [
←
/
→
/10KEY] key is pressed, setting is changed. When [ENTER/START] key is pressed, set-
ting is written into the EEPROM. The machine goes into the sub code entry standby mode.
∗
Applied only to the Japan model. However, there is no schedule to produce the Japan model. Set-
ting is reflected only when ON with test command 43-09.
[Operation]
The operation is similar to test command 21-01.
Main
code
Sub
code
Contents
Details of function/operation
Code
Shift temperature (°C)
Remark
0
±0
Default
1
-8
2
-6
3
-4
4
-2
5
±0
6
+2
7
+4
8
+6
9
+8
Code
Shift temperature (°C)
Display item
Remark
0
Cancel
OFF
Default
1
Setting
ON
Code
Shift temperature (°C)
Remark
0
160
1
165
2
170
3
175
4
180
5
185
6
190
7
195
Default
8
200