AT+HTTPUA= lwip1.3.2
Set HTTP User-Agent area
If send “AT+HTTPDT”, the data packet will be sent as the following instance including the two
new line:
POST /abcd HTTP/1.1
Connection:keep-alive
User-Agent:lwip1.3.2
Content-Length:0
Host:192.168.0.127:8999
If send AT+HTTPDT=abcd, the data packet will be sent as the following instance:
POST /abcd HTTP/1.1
Connection:keep-alive
User-Agent:lwip1.3.2
Content-Length:4
Host:192.168.0.127:8999
abcd
The data received from HTTP server will be output to serial port and end with “+ok”.
If the module hasn’t received data from HTTP server for 5 second, it will cut the TCP link with
HTTP server.