INSTALLATION INSTRUCTIONS
a) Installing or replacing the lamp
CAUTION
Only install the lamp with the device unplugged from the mains
.
The lamp has to be replaced when it is damaged or deformed.
Before replacing the lamp let the lamp cool down, because during operation, the lamp can
reach very high temperature.
During the installation of the lamps do not touch the glass bulbs bare handed. Always use a cloth to handle
the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which the device was
designed for.
For the installation, you need one Philips MSR 575/2
Procedures:
2
1
3
4
1)
Unscrew the 4 screws (A, B, C, D) on the bottom of the housing, holding the plate where the lamp is
underneath.
2)
Gently pull the socket holder using the knob in the middle.
3)
Carefully insert the lamp into the socket. Please remember there is only one way to insert the lamp.
Gently slide the lamp and its lamp holder back into place and fasten the 4 screws.
4)
On the access plate there are 3 screws marked 1,2 and 3.which are used to adjust the lamp holder in the
lamp housing. You can adjust the 3 screws to fine-turn the position of the lamp to get the maximum light
output as shown below.
1
3
2
A
B
C
D
Please remember the lamp is not a hot-restrike type, you must wait for approximately 15 minutes after
having turned off the lamp before you can turn it back on again.
CAUTION
Do
not operate this device with open cover