G
GB
B
appendix
I
D
F
E
Powerlight 1212 version1.01
9
1.3.3 DMX signal cable construction
Power Light P1212 has a DMX 512 input that uses standard XLR 5-pin connectors.
When connecting, screened cable in compliance with EIA RS-485 specifications and with the
following characteristics must be used:
- 2 conductors plus screen
- 120 Ohm impedance
- low capacity
- maximum transmission rate 250Kbaud.
Connecting the cable:
see diagram, taking care to ensure that the screen is connected to Pin 1
Attention: the cable screen (braid) must NEVER be connected to the system's
ground, as this would cause faulty unit or controller operation.
1.3.4 Example of DMX line connection
To avoid the risk of faulty operation, follow the following indications:
Maximum cable length:
500m
Maximum N° of units connected:
32
Cable run:
Avoid running the cable alongside power lines.
Termination:
120 ohm resistor across Pins 2 and 3 of the last unit.
input
output
see top cover for pin out
see top cover for pin out
DMX controller
DMX line
DMX Termination
(Last unit)
CH1
CH2
CH3
CH4
CH8
CH7
CH6
CH5
CH9
CH10
CH12
CH11
CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE
TO CONSULT THE MANUAL BEFORE EVERY OPERATION
MAX 12A/CH 110/220V
apparecchio non per uso domestico
fixture not for domestic use
MAIN 3/N/PE 380V 50/60HZ -32Kw Max
OUT
IN
DMX 512
Disconnect fixture before opening
Non aprire prima di avere tolto la tensione
CH1
CH2
CH3
CH4
CH8
CH7
CH6
CH5
CH9
CH10
CH12
CH11
CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE
TO CONSULT THE MANUAL BEFORE EVERY OPERATION
MAX 12A/CH 110/220V
apparecchio non per uso domestico
fixture not for domestic use
MAIN 3/N/PE 380V 50/60HZ -32Kw Max
OUT
IN
DMX 512
Disconnect fixture before opening
Non aprire prima di avere tolto la tensione
CH1
CH2
CH3
CH4
CH8
CH7
CH6
CH5
CH9
CH10
CH12
CH11
CONSULTARE IL MANUALE PRIMA DI OGNI OPERAZIONE
TO CONSULT THE MANUAL BEFORE EVERY OPERATION
MAX 12A/CH 110/220V
apparecchio non per uso domestico
fixture not for domestic use
MAIN 3/N/PE 380V 50/60HZ -32Kw Max
OUT
IN
DMX 512
Disconnect fixture before opening
Non aprire prima di avere tolto la tensione
Pilot
1 or 21
2 or 22
3 or 23
4 or 24
5 or 25
6 or 26
7 or 27
8 or 28
9 or 29 10 or 30 11 or 31 12 or 32 13 or 33 14 or 34 15 or 35 16 or 36 17 or 37 18 or 38 19 or 39 20 or 40
program
chase
psycho
preset
unit
step
page
store
edit
levels
times
copy
enter
play
extra
lamp
reset
smpte
rec
on/off
u n i v e rs a l d m x c o n t ro l l e r
0
10
20
30
40
50
60
70
80
90
100%
2000
2000
programming keyboard
multifunction keyboard
grand master
operations
utility
memory obj
memory
1 - 20
21 - 40
setup
pan
tilt
D I M M R
0
C O L O R
0
G O B O S
0
S H U T T
0
R O T G B
0
F R O S T
0
- 0
- 0
1
2
3
4
5
COMMON
DMX-
DMX+
www.audiovias.com