The i-5 Series can operate on any 208–240 V, 50/60 Hz AC mains power supply, and it draws approximately 2A at full power.
Connect the fixture to AC power by mounting a power connector to the bare ended mains cable. The fixture must be grounded/
earthed and be able to be isolated from AC power. The AC power supply must incorporate a fuse or circuit breaker for fault protection.
The power cable color coding is given in figure 7:
•
Connect the black wire to live
•
Connect the white wire to neutral
•
Connect the green/yellow wire to ground (earth)
For a temporary outdoor installation the mains cable must be
fitted with a grounded connector intended for exterior use.
For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction’s
ingress protection (IP) rating must be suitable for the location. Always use a junction box with a proper IP class suitable for the
environment.
When installing standard type C circuit breakers there will be no limitations due to the fixture in-rush current.
Due to the nominal current of the fixture, ensure that no more than:
•
4 fixtures are connected through the same type C, 10A circuit breaker.
•
7 fixtures are connected through the same type C, 16A circuit breaker.
For assistance with alternative configurations, contact your SGM representative.
NOTE: In POI versions, the power is wired as the standard versions by mounting a power connector to the bare ended mains
cable. Please refer to pages 20-21 for connecting AC power in POI fixtures.
After connecting the i-5 to power, run the on-board test by selecting the option “TEST→ AUTOMATED TEST” in the menu, to ensure
that the fixture and each LED are functioning correctly. POI versions have to be tested through RDM.
CAUTION!!
Do not open the fixture to replace the supplied power cable.
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
Connecting AC power
The fixture must be grounded/
earthed and be able to be isolated
from AC power. The AC power
supply must incorporate a fuse or
curcuit breaker for fault protection.
Color
Black
White
green/yellow
Conductor
live
neutral
ground (earth)
Symbol
or
L
N
Wire
Figure 7: Connecting AC Power
The fixture can be tilted from 0° - 190°.
In i-5 standard versions, there is no need for any special tools to adjust the tilt angle.
Follow the steps below for adjusting the tilt in standard i-5:
1.
Loosen the two tilt screws (one on each side) by turning them counter-clockwise.
2.
Tilt the fixture to the angle desired and hold it.
3.
Lock the position by re-tightening both tilt lock screws clockwise.
If you feel resistance when tilting the fixture, you might not have loosened the tilt screws enough.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes before handling.
Exterior surface temperature after 5 min. operation = 43 °C (109 °F). Steady state = 60 °C (140 °F).
NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small
pig-nose key, depending on the type of fixture. See page 20 to know more about the tilt lock in i-5 POI.
Figure 6: i-5 Standard tilt lock