19
Figure 16: SGM Addressing tool
The SGM POI versions are designed for permanent outdoor installation and are IP66-rated or higher. POI versions are designed for
use in maritime and offshore environments, as per the C5-M corrosion-resistance class.
Physical differences
The POI version differs from the standard version by having fixed-chassis power and DMX cables, and heavy-duty cable glands. The
display and control panel have been removed.
Configuration
The i-5 POI Series does not include a display, therefore it has to be configured through RDM (Remote Device Management). See
“RDM” on page 17 for more information.
In POI versions, the DMX address and DMX mode can only be set through RDM. When addressing through USB powered DMX /
RDM devices, ensure DMX link is terminated, and keep a short cable length as far as possible.
Regarding the DMX modes for POI, they are the same as the standard i-5 Series. Visit www.sgmlight.com to see all DMX charts
available under the respective product, or upon request via [email protected].
PLEASE NOTE!!
Remote Device Management (RDM) requires a correct DMX cabled installation and termination.
When setting addresses through RDM and using USB dongles, disable the USB selective suspend to ensure a proper
voltage on the DMX link. If any lag or trouble occurs when addressing, decrease the cable length range to <12 m. and only
address one fixture at a time.
LED Indicator
The LED indicator is located next to the DMX input cable, and shows the current status of the
fixture.
The LED indicator has two different colors and three possible stages: static, flashing, or off.
• Static green:
fixture is powered and receiving DMX signal.
• Flashing green:
fixture is powered on without receiving DMX signal.
•
Static/flashing red:
an error message is stored; review via the SGM RDM Addressing
Tool, reboot the fixture, or contact SGM support for diagnostic help.
• Off:
fixture is off or indicator LED is set to auto dimming (set via RDM).
SGM Addressing Tool
SGM provides a Windows software tool designed to allow the user to address and configure the fixtures through RDM. Changing the
settings is done in the exact same way as it is in the display.
This tool is available for download at www.sgmlight.com, and has to be used with the SGM USB 5-Pin-XLR Uploader cable (available
from your SGM dealer).
POI Permanent Outdoor Installation
P-5 POI
B
A
A:
44 x 10W LEDs
B:
P-5 Tilt lock
C:
Cooling fans
D:
DMX in and out
E:
Wireless antenna socket (POI n/a)
F:
RFID Antenna (POI n/a)
G:
OLED Display (POI n/a)
H:
Control panel (POI n/a)
I:
GORE-TEX membrane
J:
Power connection
K:
Holes for Omega bracket / M-10 screws (x4)
L:
Safety wire attachment point
M:
P-5 POI Tilt lock (POI only)
N:
LED indicator (POI only)
C
H
F
J
K
G
D
E
I
L
M
N
Figure 1
5: i-5 POI LED indicator
Summary of Contents for I-SERIES
Page 27: ...27 User Notes...