background image

19

Figure 16: SGM Addressing tool

The SGM POI versions are designed for permanent outdoor installation and are IP66-rated or higher. POI versions are designed for 

use in maritime and offshore environments, as per the C5-M corrosion-resistance class.

Physical differences

The POI version differs from the standard version by having fixed-chassis power and DMX cables, and heavy-duty cable glands. The 

display and control panel have been removed.

Configuration

The i-5 POI Series does not include a display, therefore it has to be configured through RDM (Remote Device Management). See 

“RDM” on page 17 for more information.
In POI versions, the DMX address and DMX mode can only be set through RDM. When addressing through USB powered DMX / 

RDM devices, ensure DMX link is terminated, and keep a short cable length as far as possible. 
Regarding the DMX modes for POI, they are the same as the standard i-5 Series. Visit www.sgmlight.com to see all DMX charts 

available under the respective product, or upon request via [email protected].

PLEASE NOTE!!
Remote Device Management (RDM) requires a correct DMX cabled installation and termination.
When setting addresses through RDM and using USB dongles, disable the USB selective suspend to ensure a proper 

voltage on the DMX link. If any lag or trouble occurs when addressing, decrease the cable length range to <12 m. and only 

address one fixture at a time. 

LED Indicator

The LED indicator is located next to the DMX input cable, and shows the current status of the 

fixture.
The LED indicator has two different colors and three possible stages: static, flashing, or off.

•  Static green:

 fixture is powered and receiving DMX signal.

•  Flashing green: 

fixture is powered on without receiving DMX signal.

• 

Static/flashing red:

 

an error message is stored; review via the SGM RDM Addressing 

Tool, reboot the fixture, or contact SGM support for diagnostic help.

•  Off: 

fixture is off or indicator LED is set to auto dimming (set via RDM).

SGM Addressing Tool

SGM provides a Windows software tool designed to allow the user to address and configure the fixtures through RDM. Changing the 

settings is done in the exact same way as it is in the display.

This tool is available for download at www.sgmlight.com, and has to be used with the SGM USB 5-Pin-XLR Uploader cable (available 

from your SGM dealer).

POI Permanent Outdoor Installation

 

P-5 POI

 

B

A

A:

 44 x 10W LEDs

B:

 P-5 Tilt lock 

C:

 Cooling fans 

D:

 DMX in and out 

E:

 Wireless antenna socket (POI n/a)

F:

 RFID Antenna (POI n/a)

G:

 

OLED Display (POI n/a) 

 

H:

 Control panel (POI n/a)

I:

 GORE-TEX membrane 

J:

 Power connection

K:

 Holes for Omega bracket / M-10 screws (x4)

L:

 Safety wire attachment point

M:

 P-5 POI Tilt lock (POI only)

N:

 LED indicator (POI only)

C

H

F

J

K

G

D

E

I

L

M

N

 

Figure 1

5: i-5 POI LED indicator

Summary of Contents for I-SERIES

Page 1: ...USER MANUAL I SERIES I 5 RGBW POI I 5 RED POI I 5 GREEN POI I 5 BLUE POI I 5 WHITE POI I 5 UV POI...

Page 2: ...es disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained...

Page 3: ...l device 10 Configuring the device for DMX control 11 Setting a static color manually 12 Using standalone operation 12 Fixture personality settings 13 Fixture properties 14 Control menu part I 15 Cont...

Page 4: ...height to prevent injury due to falls For Permanent Outdoor Installations POI ensure that the fixture is securely fastened to a load bearing surface with suitable corrosion resistant hardware For a t...

Page 5: ...ixing and adjustable color temperature correction CTC from 2 000K to 10 000K i 5 RGBW only Optional accessories such as barndoors diffusers and anti glare shields Optional internal honeycomb to elimin...

Page 6: ...acket with fasteners standard only 1 x Omni CRMX Antenna standard only 1 x Spanner with magnet POI only 4 x M 10 screws POI Only Safety information leaflet Location application The standard fixture is...

Page 7: ...e materials cables or surfaces to be illuminated within 0 3 m 12 in of the fixture 7 Check that there is no risk of the head yoke colliding with other fixtures or structures i 5 Mounting bracket The s...

Page 8: ...to pages 20 21 for connecting AC power in POI fixtures After connecting the i 5 to power run the on board test by selecting the option TEST AUTOMATED TEST in the menu to ensure that the fixture and e...

Page 9: ...e or through RDM Please note In POI versions there is no display mounted in the fixture The adjustments are made through RDM See page 19 for more information The OLED display is the human interface of...

Page 10: ...isn t connected to maintain IP rating Attaching the CRMX wireless receiver POI n a The CRMXTM wireless receiver antenna is an included accessory and is recommended for long range wireless operation Be...

Page 11: ...ddress sharing can be useful for diagnostic purposes and symmetrical control Set edit DMX address The DMX address is shown on the OLED display in the control panel To change the address setting press...

Page 12: ...atic color go to MANUAL QUICK COLOR in the menu Note that once the MANUAL QUICK COLOR settings are changed the fixture will be set by default to automatically start in quick color mode whenever it is...

Page 13: ...t the default fan speed by going to SETTINGS FAN MODE in the menu NOTE In POI version the fan mode adjustment is possible through RDM Setting the LED refresh rate Frequency When using LED lighting wit...

Page 14: ...Blue White and UV The i 5 RGBW version contains 148 Red 51 Green 48 Blue and 56 White LEDs and can be operated in RGB calibrated mode which ensures that colors are compatible across the range of SGM...

Page 15: ...ne program Quickcolor Default operating mode Fixture starts up with defined quickcolor Startup Program 1 3 Select program to run at start up program 1 is default Only used if the startup mode is set t...

Page 16: ...g internal sequence or Quick Color Master Slave Set fixture to operate as Master or Slave fixture Editor Program 1 3 Currently selected program 1 2 or 3 Scene 1 24 Currently selected scene 1 24 Red i...

Page 17: ...ons allowed Name 0x0080 GET Device Model Description 0x0081 GET Manufacturer Label 0x0082 GET SET Device label 0x0090 SET Factory Defaults 0x1000 GET SET Identify 0x00F0 GET SET DMX Start Address 0x00...

Page 18: ...pect and enter the correct DMX address or mode DMX cable polarization is inverted pin 2 3 Install a phase inverter to reverse the polarity or replace cables DMX link is not terminated Install a XLR 12...

Page 19: ...cabled installation and termination When setting addresses through RDM and using USB dongles disable the USB selective suspend to ensure a proper voltage on the DMX link If any lag or trouble occurs w...

Page 20: ...nstallation and rigging The SGM Omega bracket not included or a customized bracket is needed to install the fixture Consider the dimensions below of the i 5 POI base for customized mounting brackets p...

Page 21: ...low Ground DMX IN Data DMX IN Data DMX OUT Data DMX OUT Data SGM POI DMX Cable Shield GND White DMX in Data Red DMX in Data Shield GND Black DMX out Data Yellow DMX out Data Junction box DMX cable DMX...

Page 22: ...he accessory holder The i 5 Series barndoors are also compatible with the use of color frame and diffusion filters Floorstand The i 5 Series have available an optional floorstand ideal when there is a...

Page 23: ...accessory that must be fitted between the glass front and the optics Although is must be ordered as an accessory the fixture can be customized with the honeycomb at request when ordering Note This acc...

Page 24: ...l SGM IP rated fixtures made for testing the IP validity after having reassembled the fixture In order to ensure the IP rating of the i 5 Series it s highly recommended that the fixture is always vacu...

Page 25: ...5 Series can be ordered in any RAL color and with Honey Comb at request Contact your local SGM dealer for ordering customized color housings or for more information i 5 Series accessories Omega brack...

Page 26: ...2014 35 EU Low Voltage Directive Conforms to 2014 30 EU EMC Directive Conforms to 2011 65 EU RoHS2 Directive Conforms to ANSI UL Std 1573 Certified to CSA Std C22 2 No 166 Approvals and certification...

Page 27: ...27 User Notes...

Page 28: ...28 SGM Light A S Sommervej 23 8210 Aarhus V Denmark Tel 45 70 20 74 00 info sgmlight com www sgmlight com...