Channel A 

 

 

 

 
0 - 5 = OFF 
6 -255 = Volume Control 

( 5% - 100%; 255 is the maximum output) 

 
The Fazer 1000 have on-board DMX control. These models use 2 channel to control volume output operation 
and Fan operation. Each channel has a value range of 0 to 255. Timer functions such as duration and interval 
can be programmed using the DMX controller or the DMX control software being used by lighting and effects 
operator. 
 

If Channel A has a value from 0 to 5, the unit is OFF. 

 
Between the values 6 to 255 the volume of fog output is regulated.    With 6 being the minimum volume of 
fog produced and 249 approaching the maximum.    The volume output rises as the DMX value is increased. 
 
Note: In the example above, if the machine were assigned the DMX address of 124, Channel A would 
correspond to DMX address 124 and channel 125 will be selected automatically for fan control.   
 
In general, SGM Fazer 1000 with onboard DMX conform to the following performance specifications: 
1. Average Operating temperature = 250ºC 
2. Fazer 1000’s Nonstop Burst cannot be controlled or set from DMX; however, you can achieve the nonstop 
output by adjusting the volume below 50% on your X-10 or X-30. 
 

16.

 

L

IMITED 

W

ARRANTY

 

 

The unit is guaranteed for 24 months from the date of purchase against manufacturing material 
defects. 

 

Breakdown caused by carelessness and improper use of the fixture is excluded.   

 

The guarantee is no longer valid if the unit has been tampered with or repaired by unauthorized 
personnel. 

 

Replacement of the fixture is not foreseen by the    guarantee. 

 

External parts, knobs, switches, removable parts and lamps are excluded from the guarantee 

 

Transport costs and related risks are borne by the fixture’s owner. 

 

The guarantee is valid to all effects only on presentation of the guarantee certificate to the 
manufacturer or the nearest SGM technical assistance centre.   

 

Always quote the unit’s serial number and model when contacting your reseller for information or 
assistance. 

NOTE:

 USE OF ANY FLUID OTHER THAN SGM FOG FLUID WILL VOID WARRANTY. 

6-255 

0-5 

www.audiovias.com

Summary of Contents for FAZER 1000

Page 1: ...0 Module 5 X 10 Remote Control External View 6 8 Control Module Operation For SGM X 30 Module 6 X 30 Remote Control External View 6 9 SGM On Board DMX Module Settings 6 10 Maintenance 7 11 Storage 7 1...

Page 2: ...your SGM Fog Machine before filling its tank Keep fog machine upright Unplug the machine when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the hous...

Page 3: ...n the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your SGM dealer for assistance The shipping carton should include the foll...

Page 4: ...If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important tha...

Page 5: ...in for the VOLUME function Additionally if you press 1unit UP beyond value 100 or 1 unit DOWN below 1 you can then activate continuous fogging with the sub menu NON STOP BURST by pressing FUNCTION aga...

Page 6: ...DMX use only 1 channel to control volume output operation On Fazer 1000 use 2 channels to control both fog volume and fan volume For FAZER 1000 the fans have 3 levels of fan operation speed low mid r...

Page 7: ...ly replacement and repair charges 11 STORAGE 1 When storing run distilled water not tap water through the system as described in the cleaning regimen above This will help avoid any particles condensin...

Page 8: ...l Inlet Socket 3 Pin XLR for DMX 13 Control Outlet Socket 3 Pin XLR for DMX 14 Control Inlet Socket 5 Pin XLR for Remote 15 Control Outlet Socket 5 Pin XLR for Remote Assembling Please be certain that...

Page 9: ...DMX conform to the following performance specifications 1 Average Operating temperature 250 C 2 Fazer 1000 s Nonstop Burst cannot be controlled or set from DMX however you can achieve the nonstop out...

Reviews: