1.

 

I

NTRODUCTION

 

Thank you for choosing an SGM    Fazer 1000.    You now own a rugged and powerful state-of-the-art machine.   
For SGM Fazer 1000 model Machine, you will have an optional function of W-DMX.    Please refer to W-DMX 
Instruction Manual.    Prior to use, we suggest that you carefully read all of the instructions.    By following the 
suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of 
your SGM Fog Machine for years to come. 

 
 
 

Please follow these operation, safety and maintenance instructions to ensure a long and safe life 

for your fog machine. 

 

 

Caution! 

Risk of electric shock.    Disconnect the appliance from the electric supply before 
removing the cover.    . 

 

Note:

 there are no user serviceable parts inside. 

 

2.

 

I

MPORTANT 

S

AFEGUARDS

 

Danger of Electric Shock 

 

 

Keep this device dry. 

 

For inside use only.    Not designed for outside use. 

 

For all models, use 3-prong grounded electrical outlet only.    Prior to use take 
care to determine that the unit is installed at the rated voltage. 

 

Always unplug your SGM Fog Machine before filling its tank. 

 

Keep fog machine upright. 

 

Unplug the machine when not in use. 

 

This machine is not water- or splash-proof.    If moisture, water, or fog liquid gets 
inside the housing, immediately unplug the unit and contact a service technician 
or your SGM dealer before using it again. 

 

No user serviceable parts inside.    Refer to your SGM dealer or other qualified 
service personnel. 

 

Danger of Burns 

 

 

For adult use only.    Never leave the unit running unattended. 

 

Never aim the output nozzle directly at people. 

 

Fog machine output area is very hot.    Avoid coming within 60 cm of the output 

nozzle during operation. 

 

Locate the fog machine in a well-ventilated area.    Never cover the unit's vents.   

In order to guarantee adequate ventilation, allow a free air space of at least 20 
cm around the sides and top of the unit. 

 

Never aim the output nozzle at open flames. 

 

If the supply cord is damaged, it must be replaced by manufacturer or its service 

agent or similarly qualified personnel in order to avoid a hazard. 

 

The output nozzle becomes very hot during operation (3000C).    Keep 

flammable materials at least 50 cm away from the nozzle. 

 

Always allow your SGM Fazer 1000    to cool down before attempting to clean or 

service it. 

www.audiovias.com

Summary of Contents for FAZER 1000

Page 1: ...0 Module 5 X 10 Remote Control External View 6 8 Control Module Operation For SGM X 30 Module 6 X 30 Remote Control External View 6 9 SGM On Board DMX Module Settings 6 10 Maintenance 7 11 Storage 7 1...

Page 2: ...your SGM Fog Machine before filling its tank Keep fog machine upright Unplug the machine when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the hous...

Page 3: ...n the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your SGM dealer for assistance The shipping carton should include the foll...

Page 4: ...If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important tha...

Page 5: ...in for the VOLUME function Additionally if you press 1unit UP beyond value 100 or 1 unit DOWN below 1 you can then activate continuous fogging with the sub menu NON STOP BURST by pressing FUNCTION aga...

Page 6: ...DMX use only 1 channel to control volume output operation On Fazer 1000 use 2 channels to control both fog volume and fan volume For FAZER 1000 the fans have 3 levels of fan operation speed low mid r...

Page 7: ...ly replacement and repair charges 11 STORAGE 1 When storing run distilled water not tap water through the system as described in the cleaning regimen above This will help avoid any particles condensin...

Page 8: ...l Inlet Socket 3 Pin XLR for DMX 13 Control Outlet Socket 3 Pin XLR for DMX 14 Control Inlet Socket 5 Pin XLR for Remote 15 Control Outlet Socket 5 Pin XLR for Remote Assembling Please be certain that...

Page 9: ...DMX conform to the following performance specifications 1 Average Operating temperature 250 C 2 Fazer 1000 s Nonstop Burst cannot be controlled or set from DMX however you can achieve the nonstop out...

Reviews: