background image

SGM 

   

GB 

 

Fazer 1000 

 

 

10.

 

M

AINTENANCE

 

Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid container and 
the fog machine liquid tank immediately after filling. After every 40 hours of continuous operation, it is 
recommended to run a cleaning solution composed of 80% distilled water and 20% ACETIC ACID through 
the system to prevent the accumulation of particulate matter in the heating element.     
The recommended cleaning regimen is as follows: 

1

 

Empty all fog liquid from the machine. Add cleaning solution (about 500ml) to the tank. Plug unit in and     
begin warming up. 

2

 

Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry. 

3

 

Replace nozzle. 

4

 

Cleaning is now complete. Refill with fog liquid. Run the machine briefly to clear any cleaning solution 
from the pump and heater. 

5

 

Do not operate the fog machine without liquid at any time.   

Note

: All fog machines are prone to clogging due to the thick consistency of fog liquid and the high 

temperature at which it vaporizes. However, a properly maintained fog machine should provide years of 
reliable use. 
Clean with a dry cloth only. Store dry.    Cleaning your fog machine regularly will help reduce costly 
replacement and repair charges. 
 

11.

 

S

TORAGE

 

1.

 

When storing run distilled water (not tap water) through the system as described in the cleaning regimen 
above. This will help avoid any particles condensing inside the pump or heater. 

2.

 

It is strongly recommended to test-run the machine on a monthly basis in order to achieve its best 
fogging condition. A test-run consists of warming up the machine followed by a few minutes of emission. 
After that, follow Step 1 under Storage. 

Cleaning your fog machine regularly will help reduce costly parts replacement and repair charges. 

 

12.

 

P

ERFORMANCE 

N

OTES

 

It is recommended that you set the Fan output at 100% and Fog Volume output at 15-20%. With such setting, 
you will have continuous output of very fine haze effect 
Whenever enormous effect is required, press Manual key to emit faze at 100% output instantly. 
For quiet operation, lower down Fan output as desired. 
Fazer 1000 has a recycling period after long bursts(About 35- 40seconds) when the machine will shut itself 
down for a short period (about 80seconds) in order to heat up again. During this time, no fog can be 
produced.     
 

13.

 

S

PECIFICATIONS

 

MODELS 

FAZER 1000 

POWER 

AC100V - AC120V - AC230V - AC240V, 50Hz-60Hz 

HEATER 

1,000W 

OUTPUT 

105 m3/min 

OUTPUT PRESSURE 

0.686 pa 

HEAT UP TIME 

10Min 

FLUID CONSUMPTION RATE 

45 min / liter (100% Output) 
120 min / liter (30% Output) 

TANK CAPACITY 

2,4Liter 

WEIGHT 

20,5kg 

DIMENSIONS (LxWxH) 

653x275x281 mm 

 

www.audiovias.com

Summary of Contents for FAZER 1000

Page 1: ...0 Module 5 X 10 Remote Control External View 6 8 Control Module Operation For SGM X 30 Module 6 X 30 Remote Control External View 6 9 SGM On Board DMX Module Settings 6 10 Maintenance 7 11 Storage 7 1...

Page 2: ...your SGM Fog Machine before filling its tank Keep fog machine upright Unplug the machine when not in use This machine is not water or splash proof If moisture water or fog liquid gets inside the hous...

Page 3: ...n the event that the unit s housing or cable is damaged do not plug it in and do not attempt to use it until after contacting your SGM dealer for assistance The shipping carton should include the foll...

Page 4: ...If your model includes a mounting bracket designed for overhead installation it may be installed at floor level or suspended overhead If the unit is to be mounted using the bracket it is important tha...

Page 5: ...in for the VOLUME function Additionally if you press 1unit UP beyond value 100 or 1 unit DOWN below 1 you can then activate continuous fogging with the sub menu NON STOP BURST by pressing FUNCTION aga...

Page 6: ...DMX use only 1 channel to control volume output operation On Fazer 1000 use 2 channels to control both fog volume and fan volume For FAZER 1000 the fans have 3 levels of fan operation speed low mid r...

Page 7: ...ly replacement and repair charges 11 STORAGE 1 When storing run distilled water not tap water through the system as described in the cleaning regimen above This will help avoid any particles condensin...

Page 8: ...l Inlet Socket 3 Pin XLR for DMX 13 Control Outlet Socket 3 Pin XLR for DMX 14 Control Inlet Socket 5 Pin XLR for Remote 15 Control Outlet Socket 5 Pin XLR for Remote Assembling Please be certain that...

Page 9: ...DMX conform to the following performance specifications 1 Average Operating temperature 250 C 2 Fazer 1000 s Nonstop Burst cannot be controlled or set from DMX however you can achieve the nonstop out...

Reviews: