8.7.2.2.5 -
Direction
This parameter enables the flow direction measurement
Default: Fwd (
forward
)
Range: Fwd (
forward
); Rev (reverse); Bid. (bidirectional)
Press the
key from run mode: the display will be as shown here next.
With
or
select the parameter setting.
Press
to confirm, the display will be as shown here next.
press the
key to exit and confirm the selection; press the
key to exit and
delete the selection.
8.7.2.2.6 -
Indication
Set what is the positive flow direction compared to the arrow on the sensor.
Default: Fwd (
forward
)
Range: Fwd (
forward
); Rev (reverse)
Press the
key from run mode: the display will be as shown here next.
With
or
select the parameter setting.
Press
to confirm, the display will be as shown here next.
press the
key to exit and confirm the selection; press the
key to exit and
delete the selection.
8.7.2.3 -
Pulse Output
Press the
key to enter the submenu “Pulse Output” .
8.7.2.3.1 -
Freq Max (Hz)
Sets the maximum frequency in relation to Qmax. The digital output is active as a
frequency output only when the parameter "Liter / Pulse" is set to 0.0.
Default: 2000.0; Range: 100.0÷5000.0
Press the
key from run mode: the display will be as shown here next.
With
or
change the digit, with
moves the cursor.
Press
to confirm, the display will be as shown here next.
press the
key to exit and confirm the selection; press the
key to exit and
delete the selection.
8.7.2.3.2 -
Liter/Pulse
Set the volume per pulse. When this parameter is set to 0.0, the digital output is
active as a frequency output (see "Max Freq (Hz)").
Default: 0.0; Range: 0.0055÷max. according to the DN
Press the
key from run mode: the display will be as shown here next.
With
or
change the digit, with
moves the cursor.
Pmag
- Setting