130
UK
6.1 Electrical characteristics of the control unit
6.2 Technical characteristics of the detection device
Analog level sensor:
• Signal 0 - 5 V
• Input voltage 0 - 5 V
6.3 Dimensions of the SMART remote control box
6.4 Transport
For all transportation, the control panel must be switched off.
Environmental transport conditions
6.5 Connecting the control unit
On the SANIFOS
®
500, the motor and float cables must be connected to the SMART control box.
Preparation of the conductive wires
The SANIFOS
®
500 pumping station comes as standard with the SMART remote control unit.
Key
1 Current disconnector
2 Access the menu
3 Returns
4 Menu navigation
5 Activation/deactivation of the pumps
6 Pump operation indicator light
7 Forced operation of pumps
Submersion of the control device.
Risk of death by electric shock
➜ Only use the control device in rooms safe from floods.
It is imperative to
respect the colours
of the cables
when making the
connections so
as not to cause a
malfunction.
Parameter
Value
Nominal supply voltage
1 ~ 220-240 V AC
Network frequency
50/60 Hz
Protection class
IP54
Nominal current per engine
- SANIFOS
®
110 and 250
6 A
- SANIFOS
®
500 single phase
2 x 6 A
Environmental conditions
Value
Relative humidity
85% maxi. (no condensation)
Ambient temperature
-10°C to +70°C
Connector
Conductor
PE N, L, 1, 2, 3
Disassembly length y (mm)
33
25
Stripping length x (mm)
8
8