background image

11

LIMITED WARRANTY

2 Year Warranty from Date of Purchase

Subject to the terms and conditions set out below, SFA-SANIFLO INC., (hereafter designated 

the as the Company) warrants that it will repair or replace the product or any of its component 

parts, at the Company’s discretion if it deems that the product or part it is defective or does not 

meet the rated performance due to a maufacturing or material default.
If replacement is to be issued, this will only be extended to the first year starting from the date 

of purchase. Warranty repairs will apply after such date up to the warranty’s date of conclusion.

TERMS AND CONDITIONS

The conditions of this warranty are the following:

•  The product must be installed in accordance with the use described in the enclosed 

manuals.

•  The product must be connected to a single phase 120V, 60Hz electrical outlet and wa 

not subject to any negligence, accident or exposure to harmful products or substances.

•  The alleged defect or fault must be reported either to the installer or to the Company

•  during the warranty coverage period.

•  The warranty coverage period is valid for 2 years.

PART OR PRODUCT EXCHANGE

The product may be exchanged without cost only at the sales outlet where it was purchased 

subject to the following conditions:

•  The customer must have an “authorized return number” from the manufacturer in order 

to validate exchange.

•  The customer must produce proof of purchase to validate exchange.

LIMITATIONS

1. Fill and flush mechanism are guaranteed as per OEM warranty only.

2. Vitreous china are guaranteed only for a factory defect.

3. Cost of disconnection and reconnection (ie labor charges) are not covered by the warranty 

and are end-users responsibility.

4. Cost of mail or freight when a part or parts of the system have to be repaired at the 

company are not covered by this warranty.

5. In  no  event  shall  the  company  be  liable  for  any  special,  incidental  or  consequential 

damage, loss, or injury of whatsoever nature or kind arising from or in connection with 

the product or any component thereof.

6. The guarantee is transferable only when the product remains at the same premises as 

where it was installed initialy.

Except as set forth in this Limited Warranty, the company disclaims all other warranties, 

express or implied, with respect to the product or any component thereof including, but not 

limited to, all implied warranties for merchantability and fitness for a particular purpose

For service, returns or for further inquiries, please contact one of the following addresses:

United States

SFA-SANIFLO INC. 

105 Newfield Avenue, Suite A  

Edison, NJ 08837

Toll Free:  

1-800-571-8191 

Telephone:   1-732-225-6070

Fax:    

1-732-225-6072

E-mail.:  

[email protected]

Web Site:  

www.saniflo.com

Canada

SFA-SANIFLO INC.

500 Jamieson Parkway, Unit 5

Cambridge ON N3C 0G5

Toll Free:  

1-800-363-5874

Telephone:   1-519-824-1134

Fax:    

1-519-824-1143

E-mail.:  

[email protected]

Web Site:  

www.saniflo.ca

US/CAN

Summary of Contents for SANICUBIC 1

Page 1: ...8191 USA or 800 363 5874 CDN Pour le service client les retours ou toute question technique merci d appeller le service technique de Saniflo au num ro suivant 800 571 8191 USA or 800 363 5874 CDN This...

Page 2: ...1 2 4 5 6 1 or 4 Drain 1 or 4 Drain 1 or 4 Drain 1 Drain 1 Discharge 1 Vent 1 or 4 Drain 1 or 4 Drain DRAIN 1 Drain SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP min 3 max 12 Ft 3 7 m...

Page 3: ...H x1 I x1 F x4 E x2 C x4 B x2 A x2 40 50 100 110 100x120 40x60 A B B A D C D Entire Homes or Building Structures 24 610mm min 1 1 2 Discharge Use 7mm 1 4 Socket Wrench SANICUBIC 1 IP68 120V or 220 24...

Page 4: ...3 6 5 8 7 4 C D D F E F D C D 1 1 2 Inlet 1 1 2 Inlet 4 Inlet SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP...

Page 5: ...9 10 11 12b 12a C D C D F E F D D G G G 1 2 1 1 2 Vent 1 1 2 Inlet 1 1 2 Inlet 4 Inlet 10 25 cm min SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP...

Page 6: ...H I RESET SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP RESET 12 Ft 3 7m Max 12 Ft 3 7m Max 15 Ft 4 6m Max 8 Ft 2 5m Max...

Page 7: ...1 2 2 1 3 SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP SA 12 2 1 3...

Page 8: ...1 74 28 31 28 35 34 35 65 11 61c 61b 61 63 3 12 47b 47 76 32 67 37 13 61a 80 35 34 35 28 31 28 4 45 66 15 32 67 46 92 91 93 77 71 79 78 38 90...

Page 9: ...SFA SANIFLO INC SFA SANIFLO INC 105 Newfield Avenue Suite A 500 Jamieson Parkway Unit 5 Edison NJ 08837 Cambridge ON N3C 0G5 Toll Free 1 800 571 8191 Toll Free 1 800 363 5874 Phone 1 732 225 6070 Pho...

Page 10: ...1 8 3 1 8 R5 3 3 4 SANICUBIC 1 IP68 120V or 220 240V 60 Hz 1 HP SANICUBIC 1 IP68 0 5 10 15 20 25 30 35 40 0 10 20 30 40 50 60 70 80 90 gallons minute feet Flowrate Discharge height 223 8 181 8 2 4 11...

Page 11: ...CUBICNM 04 18 SANICUBIC SANICUBIC 1 SANICUBIC 2 Operating installation manual Manuel d utilisation d installation...

Page 12: ...rer s liability for any resulting damage The operator must ensure that all maintenance inspection and installation work is carried out by qualified plumber having previously studied this opera ting an...

Page 13: ...on is equipped with several horizontal and vertical inlet openings for 1 1 2 or 4 outside diameter piping 1 and 1 1 2 outside diameter piping 2 The engine pump assembly 10 carries the pumped fluid in...

Page 14: ...oming wastewater 158 F Max 5 min Tank volume 12 gallons Usefull volume 4 6 gallons Height of low inlets from the ground 5 1 2 GrossWeight lbs including packaging and accessories SANICUBIC 2 78 lbs Was...

Page 15: ...ent In the absence of local information to the contrary the maximum back flow level corresponds to street level roadway pavements etc Extend this line after the non return loop through a larger diamet...

Page 16: ...ng parameters and values Parameter Value Max allowed temperature 104 F of the fluid up to 158 F when pumped 5 minutes max Max room temperature 122 F 5 3 Starting frequency To prevent engine overheatin...

Page 17: ...ill stop the siren in all cases but it will only turn off the red LED if the problem that triggered the alarm has been resolved Alarms from the remote box will also remain active until the problem has...

Page 18: ...must be decontaminated If necessary wear a mask and protective clothing w Observe current legal provisions for the discharge of fluids harmful to health 7 2 Maintenance and inspection operations Work...

Page 19: ...case of significant grease deposits in the tank from greasy wastewater from artisanal or industrial businesses inform the customer that they must install a grease trap upstream from the pumping statio...

Page 20: ...10 APPENDICES SANICUBIC 1 sizing diagram SANICUBIC 2 sizing diagram US CAN...

Page 21: ...date exchange The customer must produce proof of purchase to validate exchange LIMITATIONS 1 Fill and flush mechanism are guaranteed as per OEM warranty only 2 Vitreous china are guaranteed only for a...

Page 22: ...ation d autres pi ces peut annuler la responsabilit du fabricant pour les dommages en r sultant L usager doit veiller ce que tous les travaux de maintenance d inspection et d installation soient ex cu...

Page 23: ...e de broyeur La station de pompage est quip e de plusieurs orifices d entr e horizontaux et verticaux pour tuyauterie de diam tre ext rieur 1 1 2 ou 4 1 et de diam tre ext rieur 1 1 2 2 L ensemble mot...

Page 24: ...Volume utile 4 6 gallons Hauteur des entr es basses par rapport au sol 5 1 2 Poids brut lb accessoiresetemballageinclus SANICUBIC 2 78 Evacuation ext 1 1 2 ntr e ext 1 1 2 ou 4 Ventilation ext 1 1 2...

Page 25: ...est vit Remarque Sauf indications locales contraires le niveau de reflux correspond au niveau de la voirie routes trottoirs Prolongez ce conduit apr s la boucle anti retour par un tuyau d un diam tre...

Page 26: ...et valeurs suivants Param tre Valeur Temp rature max 104 F autoris e du fluide jusqu 158 F lorsque pomp 5 minutes max Temp rature ambiante max 122 F 5 3 Fr quence de d marrages Pour viter une surchauf...

Page 27: ...s tous les cas mais elle ne permettra d teindre le voyant rouge que si le probl me ayant d clench l alarme a t r solu Les alarmes du bo tier d port resteront galement actives tant que le probl me n a...

Page 28: ...mer les vannes sur les c t s entr e et refoulement Attention Le d bit aux entr es doit tre r duit au minimum pendant la r alisation des travaux 2 Couper l alimentation lectrique 7 5 V rification de l...

Page 29: ...informer le client qu il doit installer un s para teur de graisse en amont de la station de pompage Contr ler les capteurs de niveau D monter les pressostats et v rifier que les tubes plongeurs ne soi...

Page 30: ...20 ANNEXES Sch ma de dimensionnement SANICUBIC 1 Sch ma de dimensionnement SANICUBIC 2 FR...

Page 31: ...IONS 1 Les m canismes de chasse et de remplissage du r servoir sont garantis par le fabricant d origine seulement 2 La porcelaine est garantie seulement contre les d fauts de fabrication 3 La garantie...

Page 32: ......

Reviews: