- 23 -
SI 460A DIN SIZE WEIGHING INDICATOR
■
F-Function List
General Function Setting (“●” Factory default set value)
F-LIST
Subject
Default
Contents
101
Equipment No. setting – ID No.setting
01
01~99
102
Weight–Back up Mode
02
00:Normal mode
01: Weight Back up Mode(Zero)
02: Weight Back up Mode(Zero&Tare)
103
Weighing Data Save Method
(Refer page 26)
00
00: Manual: Whenever “Print” key input
01: Auto: At every steady states
02: Auto: At the first steady states
04: Manual& Auto: At every steady states
05:Manual& Auto: At the first steady
states
104
Display Up-Date Speed
09
01:Slow(1time per 1sec)
~ 09:Fast(60times per 1sec)
108
Buzzer sound (External input detection)
00
00:Buzzer sound, 01:No Buzzer sound
110
Weight Unit
00
00:kg, 01:g, 02:ton
111
Language
00
00:Korean, 01:English
201
EMPTY Range
100
00~999999
202
Auto Zero Range
00
00~99 (Unit:0.25gradation)
203
Steady Range
08
01~99 (Unit:0.25gradation)
204
Steady condition check time
10
01~99 (Unit:0.1sec.)
205
Digital Filter
20
01:Weak vibration ~ 99:Strong vibration
206
Zero key operation mode
00
00:Always active
01:Active under steady condition only
207
Tare Key operation mode
00
00:Always active
01:Active under steady condition only
209
Zero key Operation Range
02
00: Active within 2% of Max Capacity
01: Active within 5% of Max Capacity
02: Active within 10% of Max Capacity
03: Active within 20% of Max Capacity
04: Active within 50% of Max Capacity
05: Active within 100% of Max Capacity
06:No limit
210
Tare key Operation Range
02
00: Active within 10% of Max Capacity
01: Active within 20% of Max Capacity
02: Active within 50% of Max Capacity
03: Active within 100% of Max Capacity