- 23 -
SI 410 WEIGHING INDICATOR
207
Tare Key operation mode
00
00:Always active
01:Active under steady condition only
208
Tare key Setting
00
00 : Tare Key
01 : Tare Weight
209
Zero key Operation Range
02
00: Active within 2% of Max Capacity
01: Active within 5% of Max Capacity
02: Active within 10% of Max Capacity
03: Active within 20% of Max Capacity
04: Active within 50% of Max Capacity
05: Active within 100% of Max Capacity
06:No limit
210
Tare key Operation Range
02
00: Active within 10% of Max Capacity
01: Active within 20% of Max Capacity
02: Active within 50% of Max Capacity
03: Active within 100% of Max Capacity
211
Auto Zero function under Tare
state
00
00:Disuse, 01:Use
212
Tare Delay Time
00
00:Disuse, 01 ~ 10:Use (Unit:1sec.)
213
Auto tare set when weighing
starts
00
00:Disuse, 01:Use
214
Tare reset Timing
00
00:Manual, 01:Auto at empty range,
02:Auto at steady condition,
03:Auto when finish relay out is off
215
Auto Tare reset Time
00
00 : Disuse
01 ~ 09 : Use (Unit : 1 sec)
216
Hold Mode
00
00:Sample Hold,
01:Peak Hold,
02:Average Hold
217
Hold Delay Time
00
00:Disuse, 01~10:Use (Unit:1sec.)
218
Hold reset at the near zero
00
00:Disuse, 01:Use
219
Auto Hold reset Time
00
00:Disuse, 01~10:Use (Unit:1sec.)
220
Average Hold Time
10
01 ~ 99 (Unit:0.1sec.)
221
Minus (-) Mark Display
00
00:USe 01:Disuse
222
Under UNPASS/OVERLOAD
state, Weight display
00
00:Display, 01:No display