- 44 -
SI 410 WEIGHING INDICATOR
6-1-5. Modbus Memory Map
-
RO : Read Only
- RW : Read Write
- Each P/N’s set point can’t over max capacity of Indicator.
ex)35.00kg = 3,500 (0xDAC)
- When you input date and time, it should be 6digit.
ex) 1
st
January 2014 = 140101 (0x22345)
15(H) : 50(M) : 17(S) = 155017 (0x25D89)
- Refer the memory register for regarding Lamp, Error, Digital Input, Standard Key,
Special Key
- Modbus Function Codes
'03' (0x03) : Read Holding Registers
'04' (0x04) : Read Input Registers
'06' (0x06) : Write Single Registers
'16' (0x10) : Write Multiple Registers
- CRC Check Method is CRC-16.
Add-
ress
Leng-
th
Featur
e
Description
1
2
RO
Capacity
3
2
RO
None(0x00)
5
2
RO
Analog Value
7
2
RO
Span Value
9
1
RO
Division
10
1
RO
Decimal point
11
2
RO
Current Weight
13
2
RO
Tare Weight
15
2
RO
Measured
Weight
17
2
RO
Digital input
19
2
RO
Lamp
21
2
RO
Error
23
1
RO
Weighing
Mode
24
1
RO
Weighing Step
25
2
RO
Current P/N
Sub-total count
27
2
RO
Current P/N
Sub-total
Weight
33
2
RO
Grand-total
Count
35
2
RO
Grand-total
Weight
437
2
RW
Date
439
2
RW
Time
441
1
RW
Key value
443
1
RW
Relay output
444
1
RW
P/N
445
2
RW
Current P/N
Set point 1
447
2
RW
Current P/N
Set point 2
449
2
RW
Current P/N
Set point 3
451
2
RW
Current P/N
Set point 4