Compact Operating Instructions – MOVIFIT® basic
21
5
Motor connection
Electrical Installation
5.3.2
X9, (X8): Motor connection
The X8 plug connector is only available in conjunction with MOVIFIT
®
basic with dual-
motor starter
Connection
The following table provides information about this connection:
Function
Power connection for motor with brake
Connection type
Q 8/0, female
Wiring diagram
2441429259
Assignment
No.
Name
Function
1
U
Motor phase U output
2
n. c.
Not connected
3
W
Motor phase W output
4
L1
Supply of mechanical brake
(only with MOVIFIT
®
basic inverter)
5
n. c.
Not connected
6
L2_S
Supply of mechanical brake switched
(only with MOVIFIT
®
basic inverter)
7
V
Motor phase V output
8
n. c.
Not connected
PE
PE
Protective earth
8
5
3
1
2
4
PE
6
7