6.5.1
Data transfer AS-Interface master
→
MOVIFIT
®
basic
MOVIFIT
®
basic
inverter
The following table shows the 4 data bits that the AS-Interface master sends to the
MOVIFIT
®
basic inverter and the functions of the drive:
MOVIFIT
®
basic
motor starter
The following table shows the 4 data bits that the AS-Interface master sends to the
MOVIFIT
®
basic motor starter and the functions of the drive:
6.5.2
Data transfer MOVIFIT
®
basic
→
AS-Interface master
The following table shows the 4 data bits that MOVIFIT
®
basic sends back to the AS-
Interface master:
AS-Interface bit
Function
DO3
DO2
DO1
DO0
MOVIFIT
®
basic inverter
X
X
0
0
Stop
X
X
0
1
Enable CW
X
X
1
0
Enable CCW
X
X
1
1
Stop/reset
0
0
X
X
Setpoint speed = n1
0
1
X
X
Setpoint speed = n2
1
0
X
X
Setpoint speed = n3
1
1
X
X
Setpoint speed = n4
AS-Interface bit
Function
DO2
DO1
DO0
MOVIFIT
®
basic
Reversing starter
MOVIFIT
®
basic dual motor
starter
0
0
0
Stop
Stop
0
0
1
Enable CW
Enable signal for motor at terminal
X9
0
1
0
Enable CCW
Enable signal for motor at terminal
X8
0
1
1
Stop
Enable signal for both motors at X9
+ X8
1
X
X
Reset Reset
AS-Interface bit
Meaning
DI3
DI2
DI1
DI0
X
X
X
1 / 0
Ready signal
0: The MOVIFIT
®
basic drive is not ready
1: The MOVIFIT
®
basic drive is ready for operation
X
X
1 / 0
X
Manual mode
0: MOVIFIT
®
basic control via AS-Interface
1: Manual control of MOVIFIT
®
basic
X
1 / 0
X
X
Sensor input 2
0: The signal of sensor 2 = "0"
1: The signal of sensor 2 = "1"
1 / 0
X
X
X
Sensor input 3
0: Signal of sensor 3 = "0"
1: Signal of sensor 3 = "1"
X = any status
0
0
I