58
Assembly and Operating Instructions – Gear Units R..7, F..7, K..7, K..9, S..7, SPIROPLAN® W
4
Coupling of AM adapters
Mechanical Installation
5. Check the dimension A.
6. Seal the contact surfaces between the adapter and motor using a suitable sealing
compound.
7. Mount the motor on the adapter. Ensure that the coupling claws of the adapter shaft
are engaged in the plastic cam ring.
IEC AM
63 / 71
80 / 90
100 / 112
132
160 / 180
200
225
250 / 280
A
24.5
31.5
41.5
54
76
78.5
93.5
139
T
A
1.5
1.5
4.8
4.8
10
17
17
17
Thread
M4
M4
M6
M6
M8
M10
M10
M10
NEMA AM
56
143 / 145
182 / 184
213 / 215
254 / 256
284 / 286
324 / 326
364 / 365
A
46
43
55
63.5
78.5
85.5
107
107
T
A
1.5
1.5
4.8
4.8
10
17
17
17
Thread
M4
M4
M6
M6
M8
M10
M10
M10
NOTE
To avoid contact corrosion, we recommend applying NOCO
®
Fluid to the motor shaft
before mounting the coupling half.
CAUTION
Dampness might enter the adapter when mounting a motor to the adapter.
Possible damage to property
•
Seal adapter with anaerobic fluid seal.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com