Installation notes for customer shaft without contact shoulder
1. Clean the customer shaft and the inside of the hollow shaft. Ensure that all traces of
grease or oil are removed.
2. Install the stop ring and the bushing on the customer shaft.
3. Mount the torque arm to the drive unit, observe chapter "Torque arms for shaft-
mounted gear units" (page 29).
4. Apply NOCO
®
fluid on the bushing and spread it thoroughly.