10
Technical data
Input data
Operating Instructions – MOVIPRO
®
PHE..B-A15-.1X0..B-00
84
10.3
Input data
The following table shows the technical data of the inputs.
Current supply
Supply type
3-phase AC connection, TT or TN system with directly grounded star point
Input voltage range
3 × AC 380 – 500 V
Nominal input voltage
3 × AC 400 V
Nominal input current
AC 3.5 A
Nominal input current
50 – 60 Hz
Command input
Input voltage range
Active: AC 350 – 500 V
Inactive: AC 0 – 235 V
Full wave, measured against reference phase. The reference phase de-
pends on the device configuration L
X
or L
Z
. Refer to the nameplate for the
data.
Current consumption in active
state (full wave)
3 – 6 mA ± 10%
Input frequency
50 – 60 Hz
Digital inputs
Design
Compatible with IEC 61131‑2 type 3
Current consumption
5 mA
High level
DC +11 – +30 V
Low level
DC -3 – +5 V
Technical data of safety-related 24 V supply voltage
Min.
Typical
Max.
Unit
Input voltage range
18
24
30
V (DC)
Power consumption
–
3.7
4
W
Input capacitance
–
100
120
µF
Switch-on/switch-off threshold
–
7.5
–
V
Input voltage for OFF status (STO)
–
–
5
V
Permitted leakage current of the external safety
controller
–
0
10
mA
Time from disconnecting the 24 V supply until
the deactivation of the rotating field
–
25
50
ms
23576855/EN – 10/2017