5
Electrical Installation
Power bus connection examples
82
Operating Instructions – MOVIFIT
®
-FC
5.9.2
Power bus with Han-Modular
®
plug connector
Power distribution
and line protection
• SEW-EURODRIVE recommends using HARTING Power S products for power bus
project planning.
• Two lines of max. 6 mm
2
can be routed in the AC 400 V 50/60 Hz and DC 24 V
supply cable.
• The spur lines leading to MOVIFIT
®
have a cross section of 4 mm
2
and are a
maximum of 1.5 m long.
• The Han Power S distributor is available from Harting (part number 6104 202 1069).
• Supply sensor, group IV (24V_S)
In the connector of the Han Power S distributor mentioned above (part number
6104 202 1069), the 24V_S supply voltage of sensor supply group IV is jumpered
with 24V_C continuous voltage.
Accessories:
Harting provides the following accessories for the Han Power S distributor.
TIP
This example applies for the following connection box:
• Han-Modular
®
-ABOX "MTA...-H12.-...-00"
• Han-Modular
®
-ABOX "MTA...-H22.-...-00"
812456203
Type
Cable diameter
Part number
at Harting
Bushing seal for small entry
7-10 mm
0912 000 9965
10-13 mm
0912 000 9966
13-16 mm
0912 000 9967
Filler plug for small entry
0912 000 9968
Bushing seal for large entry
7-10 mm
0912 000 9969
10-13 mm
0912 000 9970
13-16 mm
0912 000 9971
16-19 mm
0912 000 9972
19-22 mm
0912 000 9973
Filler plug for large entry
0912 000 9974
Summary of Contents for MOVIFIT-FC
Page 2: ...SEW EURODRIVE Driving the world ...
Page 169: ......
Page 170: ......
Page 171: ...SEW EURODRIVE Driving the world ...