6
Startup
Startup MOVIFIT®
Operating Instructions – MOVIFIT
®
-FC
101
4. To start up the MOVIFIT
®
frequency inverter, see the section "Startup MOVIFIT
®
Frequency Inverter" (see page 104).
5. Mount the MOVIFIT
®
-EBOX on the ABOX and close it.
6. Switch on the 24V_C and 24V_S supply voltage(s). The associated control LEDs
should now light up green.
Bus termination
The bus terminating resistors are already installed in the MOVIFIT
®
-ABOX (only with
standard ABOX "MTA...-S02.-...-00" and hybrid ABOX "MTA...-S42.-...-00") and can be
activated using switch S1, see section "ABOX" (see page 14):
The following table shows the operating principle of the bus termination switch:
Bus termination ON = on
Bus termination OFF = off
(factory setting)
837515659
837519755
Bus termination switch S1
Bus termination ON = on
Bus termination OFF = off
837562251
837566347
ON
S1
ON
S1
ON
OFF
Bus
termination
Incoming
cable
Outgoing
cable
Switch
ON
OFF
Bus
termination
Incoming
cable
Outgoing
cable
Switch
TIP
When using the following connection boxes, please note:
• Hybrid ABOX "MTA...-S52.-...-00"
• Han-Modular
®
-ABOX "MTA...-H12.-...-00"
In contrast to the standard ABOX, these connection boxes require a plug-in bus termi-
nator (M12) at the last station instead of the outgoing bus connection.
0
0
I