5
Electrical Installation
Hybrid ABOX "MTA...-S42.-...-00"
Operating Instructions – MOVIFIT
®
-FC
63
5.5.3
I/O pin assignment (X21-X28)
I/Os
12 DI + 4 DI/O
Pin X21
X22
X23
(Encoder 1
connection)
X24
(Encoder 2
connection)
M12 plug connector,
standard coding, female
1
VO24-I
VO24-I
VO24-II
VO24-II
2
DI01
DI03
DI05
Encoder track B
DI07
Encoder track B
3
0V24_C
0V24_C
0V24_C
0V24_C
4
DI00
DI02
DI04
Encoder track A
DI06
Encoder track A
5
n.c.
n.c.
n.c.
n.c.
Pin X25
(Encoder 3
connection)
X26
X27
X28
1
VO24-III
VO24-III
VO24-IV
VO24-IV
2
DI09
Encoder track B
DI11
DI13/DO01
DI15/DO03
3
0V24_C
0V24_C
0V24_S
0V24_S
4
DI08
Encoder track A
DI10
DI12/DO00
DI14/DO02
5
n.c.
n.c.
n.c.
n.c.
6 DI + 2 DI/O
Pin X21
X22
X23
X24
M12 plug connector,
standard coding, female
1
VO24-I
VO24-I
VO24-II VO24-II
2
Res.
Res.
Res.
Res.
3
0V24_C
0V24_C
0V24_C
0V24_C
4
DI00
DI01
DI02
DI03
5
n.c.
n.c.
n.c.
n.c.
Pin X25
X26
X27
X28
1
VO24-III
VO24-III
VO24-IV
VO24-IV
2
Res.
Res.
Res.
Res.
3
0V24_C
0V24_C
0V24_S
0V24_S
4
DI04
DI05
DI06/DO00
DI07/DO01
5
n.c.
n.c.
n.c.
n.c.
4 DI
Pin X21
X22
X23 - X28
M12 plug connector,
standard coding, female
1
VO24
VO24
Res.
2
DI101
DI103
Res.
3
0V24_C
0V24_C
Res.
4
DI100
DI102
Res.
5
n.c.
n.c.
Res.
12 DI +
4 DI/O
MOVIFIT
®
versions with 12 DI + 4 DI/O
Function level
Fieldbus
Technology or System
All
Classic
PROFINET, EtherNet/IP, Modbus/TCP
6 DI +
2 DI/O
MOVIFIT
®
versions with 6 DI + 2 DI/O
Function level
Fieldbus
Classic
PROFIBUS or DeviceNet
4 DI
MOVIFIT
®
versions with 4 DI
Function level
Fieldbus
None
SBus slave
1
2
5
3
4
1
2
5
3
4
1
2
5
3
4
Summary of Contents for MOVIFIT-FC