6
Inspection/maintenance
Unit
Addendum to the Operating Instructions – MOVIDRIVE
®
MDR60A1320-503-01 regenerative power supply
22
6
Inspection/maintenance
6.1
Unit
If
the
specified
operating
conditions
are
observed,
the
MOVIDRIVE
®
MDR60A1320-503-00 regenerative power supply is maintenance free. Observe the
chapter "Technical repair".
6.2
Check cooling air vents
The cooling air vents can clog up in case of unclean ambient air. Check the regenera-
tive power supply units on a regular basis, depending on the degree of pollution about
every 4 weeks. Use a vacuum to clean any clogged cooling air vents.
NOTICE
Do not use any sharp or pointed objects such as knives or screwdrivers to clean the
cooling air vents.