3
Electrical installation
Terminal assignment control terminal strip X2
Addendum to the Operating Instructions – MOVIDRIVE
®
MDR60A1320-503-01 regenerative power supply
14
3.4
Terminal assignment control terminal strip X2
12
11
10
9
8
7
6
5
4
3
2
1
+
-
[1]
[2]
[3]
[4]
[5]
37346745739
[1] X2:1 to X2:4 relay collective fault
[2] X2:5, X2:6 Internal assignment for temperature monitoring. Do not connect any
cables!
[3] X2:7, X2:8 External OFF
[4] X2:9, X2:10 not assigned
[5] X2:11, X2:12 = ON / RESET
NOTICE
Do not connect any external voltage to terminals X2:5 and X2:10 because otherwise
the unit may be damaged!
Terminal
Function
Description
X2:1 NC contact
Isolated relay contacts
1)
and there is
no collective fault, the relay picks up.
2)
Collective fault signal switching capacity of the
relay contacts:
•
30 V DC 3 A
•
230 V AC 5 A
X2:2 NC contact
X2:3 NO contact
X2:4 NO contact
X2:5
Internal assignment for temperature
monitoring
X2:6
X2:7
OFF pushbutton
To switch off the regenerative power supply
X2:8
X2:9
Not assigned
X2:10
X2:11 (+24 V)
External voltage input
To switch on the regenerative power supply or
confirm faults
X2:12 (0 V)
1) When the supply voltage is present, the precharging of the DC link capacitors is complete,
2) The relay drops out in the event of an OFF command via terminals X2:7 and X2:8 and in the event of a fault message.
27789314/EN – 07/2022