26
MOVIDRIVE
®
Multi-Motor Drives
Parameters
Parameters
Master inverter
Slave inverter
P100 Setpoint source
For example, BIPOL./FIX.SETPT
•
With SBus connection: MASTER-SBus.
•
With RS-485 connection: MASTER-RS-485
•
With analog connection (AO1
→
AI1):
BIPOL./FIX.SETPT
P101 Control signal source
For example, TERMINALS
•
Not effective with SBus and RS-485
connection.
•
With analog connection (AO1
→
AI1), for
example TERMINALS.
P110 AI1 scaling
Effective with analog
connection only (AO1
→
AI1)
-
•
Always set 1 (= factory setting). Use P350 if
there is an opposite mechanical connection.
P136 Stop ramp t13
P137 Emergency ramp t14
As required
•
Same values as master inverter
P350 Change direction of
rotation 1
-
•
Set differently from the master inverter if there
is an opposite mechanical connection.
P640 Analog output AO1
Effective with analog
connection only (AO1
→
AI1)
ACTIVE CURRENT
-
P641 Scaling AO1
Effective with analog
connection only (AO1
→
AI1)
1
-
P642 Operating mode AO1
Effective with analog
connection only (AO1
→
AI1)
-10V..10V
-
P700 Operating mode 1
CFC or SERVO
CFC & M-CONTROL or SERVO & M-CTRL.
P750 Slave setpoint
•
With SBus connection: TORQUE (SBus).
•
With RS-485 connection: TORQUE (RS-
485)
•
With analog connection (AO1
→
AI1):
MASTER-SLAVE OFF
MASTER-SLAVE OFF
P751 Scaling slave setpoint
Effective with SBus and RS-485
connection only
-
•
Always set 1 (= factory setting). Use P350 if
there is an opposite mechanical connection.
P811 RS-485 group address
With RS-485 connection only: Set to the same value.
P814 SBus group address
With SBus connection only: Set to the same value.
P816 SBus baud rate
With SBus connection only: Set to the same value.
0
0
I
Summary of Contents for MOVIDRIVE compact MCH4 A Series
Page 1: ...MOVIDRIVE Multi Motor Drives Edition 10 2001 Manual 1050 9011 EN...
Page 2: ...2 Startpaket Feldbusschnittstelle UFP11A SEW EURODRIVE...
Page 4: ...4 MOVIDRIVE Multi Motor Drives Safety and warning instructions Designated use...
Page 5: ...MOVIDRIVE Multi Motor Drives 5 Application environment Safety functions Waste disposal...
Page 9: ...MOVIDRIVE Multi Motor Drives 9 Mot drive Mot Mot drive Mot drive inverter drive...
Page 25: ...MOVIDRIVE Multi Motor Drives 25 Slave inverter 03957AEN Fig 19 Number of slave axes 0 0 I...