Manual – MOVI-PLC® Application Solution "SyncCrane"
73
6
Cycle diagrams
Operation
6.9.4
Automatic mode
The following figure show synchronized positioning mode of the group with positioning
of the virtual encoder.
536575627
[1]
Automatic
mode selected
[2]
Activation of operating mode with the start input
[3]
Feedback "Axis system synchronized – ready for virtual encoder"
[4]
Positioning of the virtual encoder
mode selected
[5]
Start of movement PO2:8 input "start"
[6]
Positioning finished. PI2:3 message (virtual encoder in position) set.
[7]
Decoupling of axis system by deselecting the operating mode
PE2:3
PE67
PA1:8
PA1:12
PA1:11
PA1:13
PA2:11
PA2:8
PA2:12
PA2:13
PE2:4
[2] [3]
[5]
[1]
[4]
[6]
[7]
Summary of Contents for MOVI-PLC