Starting the SyncCrane program
Startup
5.3.5
Step 3: Scaling the virtual encoder
Scaling the virtual
encoder
A description of the input fields on this window is already included in the description for
the previous windows.
Enter the values from the already determined values from the "Scaling the synchronous
encoder" field in the "Scaling the virtual encoder" field.
511980939
NOTE
The input fields described in steps 3 are not relevant for you if you choose the "Group"
option in the dropdown menu "Individual axis/scaling factor group" described in
chapter 3 "Selecting the individual startup steps".
In this case, the values from "Scaling the synchronous encoder" are used.
0