Manual – MOVI-PLC® Application Solution "SyncCrane"
69
6
Cycle diagrams
Operation
6.9
Cycle diagrams
The following conditions apply to the cycle diagrams:
• Startup has been performed correctly
• DI00 "/Controller inhibit" = "1" (no inhibit)
• PO1:1 = "1" (Enable/halt)
• PO1:2 = "1" (Enable/stop)
• PO3 = "99" for group control or "1 ... 12" for single axis selection
The values for the dynamic parameters are transferred using the following process
output data words:
• PO8 = Setpoint velocity
• PO9 = Acceleration ramp
• PO10 = Deceleration ramp
• PO45 = Target position for positioning mode (unsynchronized)
• PO67 = Target position for automatic mode (synchronized)