Manual – MOVI-PLC® Application Solution "SyncCrane"
37
5
Starting the SyncCrane program
Startup
5.3.3
Step 1: Project settings
511973259
Field
Description
SyncCrane configuration
This input field is used to specifiy the number of individual axes in the
axis system.
The value range is limited to 1...8.
Configuration process input
data word 8...10
Use the selection fields to choose the information you want to have
transmitted via process input data words 8, 9, and 10.
Configuration of auxiliary drives
If you want to use more auxiliary drives, you have to set the selection
field to "Yes" before starting the wizard.
0