7
Mounting positions
Mounting position sheets
Assembly and Operating Instructions – Explosion-Proof Gear Units
139
7.6
Mounting position sheets
7.6.1
Key to the mounting position sheets
INFORMATION
The positions of the breather valve, oil level plug, and oil drain plug specified in the
mounting position sheets are binding and comply with the assembly specifications.
The motors are only depicted symbolically on the mounting position sheets.
INFORMATION
For gear units with solid shaft:
The displayed shaft is always on the A-side.
For shaft-mounted gear units:
The shaft with dashed lines represents the customer
shaft. The output side ( = shaft position) is always shown on the A-side.
INFORMATION
SPRIOPLAN
®
gearmotors are not dependent on the mounting position, except for
W..37 and W..47 gearmotors in mounting position M4. However, mounting positions
M1 to M6 are also shown for SPIROPLAN
®
gearmotors to assist you in working with
this documentation.
INFORMATION
SPIROPLAN
®
gearmotors W..10 to W..30 cannot be equipped with breather valves,
oil level plugs or oil drain plugs.
SPIROPLAN
®
gearmotors W..37 and W..47 are equipped with breather valves in
mounting position M4 and with oil drain plugs in mounting position M2.
INFORMATION
Some gear units can be supplied in mounting position M0. In this case, the gear unit
is delivered in a universal mounting position and can be adjusted to various mounting
positions by the customer. It may be necessary to contact SEW‑EURODRIVE.
Symbols used
The following table shows the icons used in the mounting position sheets.
Icon
Meaning
Breather valve
Oil level plug
1)
Oil drain plug
1) Does not apply to the 1st gear unit (large gear unit) of compound gear
units. See chapter "Position of the oil level plug of compound gear
units".
24804134/EN – 05/2018